Rim Exit Installation Instructions (Continued)
4
Trim Assembly Instructions
a. Check cylinder components:
Cylinders longer than 1-1/8" (29mm) require collars.
Refer to Cylinder Collar Chart (Fig. 4a).
(for Mortise, skip to Step 5)
b. If required, modify by cutting cylinder tailpiece:
Correct length is 1/16" to 3/16" (2 to 5mm)
beyond cylinder housing cam.
c. Assemble cylinder:
1. Insert cylinder into escutcheon.
2. Pass cylinder tailpiece through cylinder collar (if required) and slot in cylinder cam.
3. Fasten cylinder in escutcheon recess or collar using 2 mounting screws.
Do not overtighten screws.
d. Escutcheon Assembly (Fig. 4b):
The lever is handed (LHR shown).
Note: Lever Return Spring handing can be identified by the color of the spring:
LHR: Part Number 651F618 (Red)
RHR: Part Number 651F628 (Blue)
Rim Cylinder
Copyright © 2016, 2019, 2021, ASSA ABLOY Access and Egress Hardware Group, Inc.
All rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Cylinder Collar
(if necessary)
Cam must be postitioned as shown
when cylinder tailpiece is assembled
Escutcheon
Assembly
Fig. 4b
13
Cylinder Collar Chart
Cylinder Length
Inches
Millimeters
1-1/8"
29mm
1-1/4"
32mm
1-1/2"
38mm
Fig. 4a
*Specify Finish
Cylinder Housing Cam
(2) Cylinder Mounting Screws
(supplied with cylinder)
Collar
None
422F88*
686F98*