Danaher Motion
In order to:
Turn off the entire application.
Wire the I/O to the application.
Change the battery.
Connect/disconnect the MMC with the com-
puter workstation through the PiCPro port.
Connect/disconnect the MMC with an opera-
tor interface through the User port.
Download an application program into the
memory.
Stop the scan.
3.8

System Status Lights

Three lights on the front of the Control (Scan, Power, and Diagnostic labeled "S", "P",
and "D"), shown in
including power supply status, battery status, diagnostic status, and system status.
3.8.1

Power Status

The green Power light (P) indicates that the power supplies internal to the MMC are
working properly. If the power light (P) does not go on, or goes off during operation of
the system, check that the proper voltage is present at the MMC power connector. If it
is, turn off the main disconnect switch and replace the MMC.
3.8.2

Battery Status

Battery Status is reported for the Standalone MMC Control and the Standalone Digital
MMC Control as follows:
Standalone MMC Hardware Manual
version 15.1
Table 3-2: Maintenance Procedure Summary
Figure
3-8, provide diagnostic and operational information
Figure 3-8: Status Lights
S
Installation, Operation, & Maintenance
Turn off main disconnect (which should also
turn off all external power supplies to the appli-
cation); unplug the DC power to the MMC.
Turn off main disconnect (which should also
turn off all external power supplies to the appli-
cation); unplug the DC power to the MMC.
Turn off main disconnect (which should also
turn off all external power supplies to the appli-
cation); unplug the DC power to the MMC.
Turn off main disconnect (which should also
turn off all external power supplies to the appli-
cation); unplug the DC power to the MMC.
Turn off main disconnect (which should also
turn off all external power supplies to the appli-
cation); unplug the DC power to the MMC.
Make sure power is on (check the P light).
From the workstation - use the Stop Scan
commands in the PiCPro software.
P
D
29