Danaher Motion Standalone MMC Hardware Manual page 120

Table of Contents

Advertisement

MMC Ethernet TCP/IP Option Module
1. Connect the PC to the RS232 Com 2 Port on the Ethernet - TCP/IP module to
download the TCP/IP configuration file (connection 1 as shown in
2. Connect the PC to the PiCPro Port on the CPU to download the application LDO
(connection 2 as shown in
PiCPro
Port
Use 10Base T (10 Mbps, baseband, over twisted pair cable) to set up your Ethernet -
TCP/IP system. The table below summarizes the specifications (IEEE 802.3) for the
Ethernet connection available on the MMC Ethernet - TCP/IP module.
Item
Type of Cable
Connection
Topology
Distance
Maximum cable segment length
Data Rate
120
Figure
Figure 6-2: MMC/PC Connections
Ethernet-TCP/IP Module
MMC
ETHERNET
DIAG
GDLNK EO EI
2.
COL PREV
OUT IN
COM1
1.
OUT IN
COM2
Enable
Disable
REMOTE
PROGRAMMER
ACCESS
10 BaseT
COM1
COM2
Table 6-1: Ethernet Port Specifications
version 15.1
6-2).
2.
1.
Specification
Category 3 or 5 (5 recommended)
UTP (shielded twisted-pair)
Shielded category 5 cable is optional.
RJ-45
Star
100 M (328 ft) between transceiver (TCP/
IP module) and hub
100 M (328 ft)
10 Mbps
Standalone MMC Hardware Manual
Danaher Motion
Figure
6-2).
PC