The Rs232 Comm Ports - Danaher Motion Standalone MMC Hardware Manual

Table of Contents

Advertisement

Danaher Motion
Part Numbers:
.3 M (1.0 ft):
1 M (3.3 ft):
3 M (9.8 ft):
10 M (32.8 ft): M.1302.8301
30 M (98.4 ft): M.1302.8303
Cable type: 28 AWG, shielded, twisted pair, 8 conductor.
8-Pin RJ-45 Plug (to
Ethernet Port, face view)
Pin
1
2
3
6
4
5
7
8
Shell
6.2.2

The RS232 COMM Ports

There are two RS232 ports at the top of the module as shown in Figure 4-3. COMM 1
will be used for modem connections (future). COMM 2 is used to download your
configuration file to the MMC.
Pin descriptions for are provided in
Pin assignments are provided in
The available PiCPro Port to PC cable is described in
Standalone MMC Hardware Manual
version 15.1
Table 6-4: Ethernet Port to Ethernet Device Cables
M.1302.8285
M.1302.8287
M.1302.8289
Ethernet Device, face view)
1
8
Signal
Pin
Transmit Data +
1
Transmit Data -
2
Receive Data +
3
Receive Data -
6
None
4
None
5
None
7
None
8
Drain
Shell
MMC Ethernet TCP/IP Option Module
.6 M (2.0 ft): M.1302.8286
2 M (6.6 ft): M.1302.8288
5 M (16.4 ft): M.1302.8300
15 M (49.2 ft): M.1302.8302
8-Pin RJ-45 Plug (to
1
8
Signal
Receive Data +
Receive Data -
Transmit Data +
Transmit Data -
None
None
None
None
Drain
Table 6-5
Table 6-6
Table 6-7
Notes
Twisted
Pair
Twisted
Pair
Twisted
Pair
Twisted
Pair
123