Counting Mode (PCS)

5.2.
Selecting the counting mode
Step 1
Select the unit "pcs" using the MODE key. If the counting mode can not be selected, refer to
section "4. Weighing Units". (pcs : pieces)
Storing a unit weight
Step 2
Press the RANGE key to enter the sampling mode.
Step 3
If you want to select the number of items to be used for the sample, press the RANGE key (several
times). It may be set to 10, 25, 50 or 100.
Step 4
Place a container on the weighing pan, if necessary. Press RE-ZERO key to cancel this weight.
ex. 25 pcs is displayed in the case of 25 items.
Step 5
Place items on the pan. This number of items is the same quantity as the number displayed (10,
25, 50 or 100).
Step 6
Wait for the stabilization indicator to come on. Press the PRINT key to calculate the unit weight
and store it.
Counting items
Step 7
You are now able to count the items by placing them on the pan.
Counting mode using the ACAI function
ACAI
(Automatic Counting Accuracy Improvement) is a function that improves the accuracy of
TM
the unit weight.
tep
8
If you add a few more items, the ACAI indicator turns on. (The ACAI indicator turns off if in
overload)
Step 9
The balance re-calculates the unit weight while the ACAI indicator is blinking. Wait and do not
touch the items on the pan until the ACAI indicator turns off automatically.
Step10 You are now able to count items with a more accurate unit weight.
Step11 If you add a few more items, proceed to step 8.
The balance re-calculates a more accurate unit weight.

Percent Mode (%)

5.3.
Selecting the unit of percent mode
Step 1 Select the unit
"4. Weighing Units". ( %: percent)
Storing 100% weight
Step 2
Press the RANGE key to enter the sampling mode.
Step 3
Place a container on the weighing pan, if necessary.
Press the RE-ZERO key to cancel the container weight and possible error.
The balance displays
Step 4
Place the item of 100% weight on the pan or in the container.
Step 5
Press the PRINT key to store this 100% weight.
Step 6
Remove the item from the pan.
%
using the MODE key. If the percent mode can not be selected, refer to section
100 0
..