Replacing the MPB96 card

There is one MPB96 card in your server.
The MPB96 card is not hot-swappable and you must power down the
system before adding or replacing the card.
Requirements
Copyright © 2007, Nortel Networks
.
Lower the right side of the fan assembly into place so that it catches
under the hook. Use caution to ensure no cables are pinched
beneath the fan assembly.
Set the left side of the fan assembly into place.
Tighten the captive screw.
Connect the fan cables to the correct fan connectors on the front
panel I/O board. The fan connectors are labeled on the front panel
I/O board. Look for FAN SYS labels.
Replace the processor air duct. For instructions, see
replacing the processor air duct" (page
Replace the server cover. For instructions, see
replacing the server cover" (page
Take off the ESD strap.
Plug in the peripheral devices and Ethernet cables, connect the AC
power cords, and restart the server.
CAUTION
Risk of electrical damage
Wear an antistatic ESD wrist strap when handling cards
or boards, or when working inside the server.
Do not touch the components or gold-edged connectors
of the cards.
Place the card on an antistatic surface until you are
ready to install it.
Phillips (cross head) screwdriver, #1 and #2 bits
Replacement MPB96 card

Nortel CallPilot

600r Server Maintenance and Diagnostics

NN44200-703 01.04 Standard

5.0 25 April 2007
78).
77).
—End—