Nortel Callpilot; 600R Server Maintenance And Diagnostics; Nn44200-703 01.04 Standard - Nortel CallPilot User Manual

Nortel callpilot: user guide
Hide thumbs Also See for CallPilot:
Table of Contents

Advertisement

10
11
Copyright © 2007, Nortel Networks
.
Figure 23
Front fan assembly
Disconnect the front fan assembly cables from the server board.
Connect the following cables between the replacement front fan
assembly and the server board.
Note: Because some of the connections are difficult to reach
after you install the fan assembly, Nortel recommends that you
connect the following cables first:
a. Left fan in the fan assembly to the Sys Fan 1 connector. Use
the short cable.
b. Center fan in the fan assembly to the Sys Fan 2 connector. Use
the short cable.
c. Right fan in the fan assembly to the Sys Fan 6 connector. (Left
side of board). Route the cable next to DIMM socket 1A (DIMM
socket nearest the processor socket), then across the center of
the board, in front of the processor socket.
d. Center fan in the fan assembly to the Sys Fan 3 connector.
(Rear of board). Route the cable next to DIMM socket 1A (DIMM
socket nearest the processor socket), then to the right side of the
processor socket.
e. Left fan in the fan assembly to the Sys Fan 4 connector. (Left
side of board). Route the cable next to DIMM socket 1A (DIMM
socket nearest the processor socket), then to the right side of the
processor socket.

Nortel CallPilot

600r Server Maintenance and Diagnostics

NN44200-703 01.04 Standard

5.0 25 April 2007
Replacing the front fan assembly 85