Table 1-1. Baystack 450 Switch Led Descriptions - Nortel BayStack 450-24T Using Manual

Baystack 450 10/100/1000 series switch
Hide thumbs Also See for BayStack 450-24T:
Table of Contents

Advertisement

Using the BayStack 450 10/100/1000 Series Switch
Table 1-1.
Label
Type
Cas Dwn Stack mode
Base
Base mode
1-8
BayStack 450 Switch LED Descriptions
Color
State
Meaning
Yellow
Blinking Incompatible software revision or unable to obtain a unit
or
ID (Renumber Stack Unit table full). The unit is on the ring
Green
but cannot participate in the stack configuration.
Off
The switch is in standalone mode.
Green
On
The switch is connected to the downstream unit's
Cascade A Out connector.
Yellow
On
The Cascade A In connector (Cas Dwn) for this switch is
looped internally (wrapped to the secondary ring).
Yellow
Blinking Incompatible software revision or unable to obtain a unit
or
ID (Renumber Stack Unit table full). The unit is on the ring
Green
but cannot participate in the stack configuration.
Green
On
The switch is configured as the stack base unit.
Off
The switch is not configured as the stack base unit (or is
in standalone mode).
Blinking Stack configuration error: Indicates that multiple base
units or no base units are configured in the stack.
Yellow
On
This unit is operating as the stack configuration's
temporary base unit. This condition occurs automatically
if the base unit (directly downstream from this unit) fails.
If this happens, the following events take place:
This automatic failover is a temporary safeguard only. If
the stack configuration loses power, the temporary base
unit will not power up as the base unit when power is
restored. For this reason, you should always assign the
temporary base unit as the base unit (set the Unit Select
switch to Base) until the failed unit is repaired or replaced.
The two units directly upstream and directly
downstream from the failed unit automatically wrap
their cascade connectors and indicate this condition
by lighting their Cas Up and Cas Dwn LEDs (see Cas
Up and Cas Dwn description in this table).
If the temporary base unit fails, the next unit directly
downstream from this unit becomes the new
temporary base unit. This process can continue until
there are only two units left in the stack configuration.
(continued)
(continued)
309978-D Rev 01