Table 4-2. Corrective Actions - Nortel BayStack 450-24T Using Manual

Baystack 450 10/100/1000 series switch
Hide thumbs Also See for BayStack 450-24T:
Table of Contents

Advertisement

Table 4-2.
Corrective Actions
Symptom
All LEDs are off.
The Activity LED for a
connected port is off or
does not blink (and you
have reason to believe
that traffic is present).
The Status LED is off.
The Status LED is
blinking.
When connecting a
console/terminal to an
operating switch
through the switch's
serial Comm Port, the
console/terminal
displays a blank
screen.
309978-D Rev 01
Probable cause
The switch is not receiving AC
power.
The fans are not operating or
the airflow is blocked, causing
the unit to overheat.
The switch is experiencing a
port connection problem.
The switch's link partner is not
autonegotiating properly.
A fatal error was detected by
the self-test.
A nonfatal error occurred
during the self-test.
This is a normal condition.
Corrective action
Verify that the AC power cord is fastened securely
at both ends and that power is available at the AC
power outlet.
Verify that there is sufficient space for adequate
airflow on both sides of the switch.
Note:
Operating temperature for the switch must
not exceed 40°C (104°F). Do not place the switch
in areas where it can be exposed to direct sunlight
or near warm air exhausts or heaters.
See the next section, "Port Connection Problems."
Cycle the power to the switch (disconnect and then
reconnect the AC power cord).
If the problem persists, replace the switch.
Cycle the power to the switch (disconnect and then
reconnect the AC power cord).
If the problem persists, contact the Nortel
Networks Technical Solutions Center.
Press [Ctrl]-C to refresh the screen.
Troubleshooting
4-7