3 Configuration
required, please use a Super Bend Resistant cable (FHV-V£BX2), or Bend Resistant cable (FHV-V
£B2/FHV-V£B).
• Smart Camera Data Unit Cables (Right-angle, bending resistance)
Item
Cable length
Cable type
Connector type
Outer diameter
Min. bending radius
Usage
environment
Material
Weight
Item
Cable length
Cable type
Connector type
Outer diameter
Min. bending radius
Usage
environment
Material
Weight
• Smart Camera Data Unit Cables (Right-angle, super bending resistance)
3-36
FHV-VULB2
2M
2 m
Bending resistance cable
Right-angle connector
7.8 ± 0.3 mm dia.
Fixed use: 40 mm, Sliding use: 65 mm
Ambient
Operating: -10 to +70°C, Storage: -25 to +85°C (with no icing or condensation)
temperature
range
Ambient
Operating & Storage: 0 to 93% (with no condensation)
humidity
range
Ambinent
No corrosive gases
atmosphere
Vibration
Oscillation frequency: 10 to 150Hz, Half amplitude: 0.35 mm, Vibration direc-
tolerance
tion: X/Y/Z, Sweep time: 8 minutes/count, Sweep count: 10 times
Shock resist-
Impact force: 150 m/s
ance
front/behind, left/right)
Mold part: PVC, Sheath part: PVC
Approx. 200 g Approx. 290 g Approx. 470 g Approx. 900 g Approx. 1780
FHV-VULB
2M
2 m
Bending resistance cable
Right-angle connector
7.9 ± 0.2 mm dia.
47 mm
Ambient
Operating: -10 to +60°C, Storage: -10 to +60°C (with no icing or condensation)
temperature
range
Ambient
Operating & Storage: 0 to 93% (with no condensation)
humidity
range
Ambinent
No corrosive gases
atmosphere
Vibration
Oscillation frequency: 10 to 150Hz, Half amplitude: 0.35 mm, Vibration direc-
tolerance
tion: X/Y/Z, Sweep time: 8 minutes/count, Sweep count: 10 times
Shock resist-
Impact force: 150 m/s
ance
front/behind, left/right)
Mold part: Nylon and Thermoplastic polyurethane, Sheath part: PVC
Approx. 220 g Approx. 310 g Approx. 500 g Approx. 980 g Approx. 1930
FHV-VULB2
FHV-VULB2
3M
5M
3 m
5 m
2
, Test direction: 6 directions, three time each (up/down,
FHV-VULB
FHV-VULB
3M
5M
3 m
5 m
2
, Test direction: 6 directions, three time each (up/down,
FHV Series Smart Camera Setup Manual (Z408-E1)
FHV-VULB2
FHV-VULB2
10M
20M
10 m
20 m
g
FHV-VULB
FHV-VULB
10M
20M
10 m
20 m
g

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac fhv7 seriesFhv-sdu10Fhv-sdu30

Table of Contents