Omron Sysmac FHV Series Setup Manual page 215

Smart camera
Table of Contents

Advertisement

• When selecting connectors, check that they are fit to cables to be used. As checking items, there
are conductor size, single or stranded wires, two or four pairs, and outer diameter.
Pin Layout
Pin assignment
Wiring
• Be sure to connect the shield for the cable to the connector hoods in both ends.
• For the connection method, follow the below as T568A style.
Pin No.
1
2
3
4
5
6
7
8
Connector hood
Precautions for Correct Use
Refer to the Vision System FH/FHV Series User's Manual for Communications Settings (Cat.
No. Z342) for details on how to set up the EtherCAT interface.
FHV Series Smart Camera Setup Manual (Z408-E1)
Pin No.
Signal name
1
Transmit data +
2
Transmit data -
3
Received data +
4
Not used
5
Not used
6
Received data -
7
Not used
8
Not used
Connector hood
Protective ground
Wire color
White/Green
Green
White/Orange
Blue
White/Blue
Orange
White/Brown
Brown
Shield
6 Power Supply and I/O Interface
Abbr.
TD +
TD -
RD +
NC
NC
RD-
NC+
NC-
FG
Wire color
Pin No.
White/Green
1
Green
2
3
White/Orange
Blue
4
5
White/Blue
Orange
6
White/Brown
7
Brown
8
Shield
Connector hood
Signal direction
Output
Output
Input
-
-
Input
-
-
-
6
6-37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac fhv7 seriesFhv-sdu10Fhv-sdu30