Assembly Of Joint Clamp; Mounting Tools - Pentair BAA A390-D.03 Select Operating Instructions Manual

Svp aseptic change-over valve
Table of Contents

Advertisement

7.4.

Assembly of joint clamp

⇒ Mounting of the clamp only in faultless condition (Fig. 1).
⇒ Pay attention to gap X and to the parallel position of the side piece (Fig. 1).
⇒ It is not allowed to mount clamps with deformed side pieces (Fig. 2).
⇒ Lubricating of the screw thread before assembly → Type of the grease IBF PW 119
⇒ Put the clamp on the clamp connection.
⇒ Put the screw with the hexagon nut (S) in the groove of the holding bracket.
⇒ Tighten the hexagon nut (S) with torque spanner
7.5.

Mounting tools

Tool
Punch 155 mm
Piercer ø5
Combination wrench (wrench size)12
forked open jaw wrench SW 17 – 19
calliper face spanner
Torque spanner with bit SW 17
Hexagonal screwdriver 3,0 mm
20
Copy of original operating instructions
SVP aseptic change-over valve, pneum. operated
DN 010 – 020, OD 0.50" – 0.75"; ISO 008 – 015
Fig.. 1
→ Locked torque 5 – 8 Nm.
It is not allowed to exceed the peak value of max. 8 Nm.
for
DN 010 – 020
OD 0.50ʺ - 0.75ʺ
ISO 008 – 015
DN 010 – 020
OD 0.50ʺ - 0.75ʺ
ISO 008 – 015
DN 010 – 020
OD 0.50ʺ - 0.75ʺ
ISO 008 – 015
DN 010 – 020
OD 0.50ʺ - 0.75ʺ
ISO 008 – 015
DN 010 – 020
OD 0.50ʺ - 0.75ʺ
ISO 008 – 015
DN 010 – 020
OD 0.50ʺ - 0.75ʺ
ISO 008 – 015
DN 010 – 020
OD 0.50ʺ - 0.75ʺ
ISO 008 – 015
Operating instructions
diaphragm – O-ring
Fig. 2
Fig. 3
Order no.
0098525
Pneum. SVP aseptic change-over
2311691
Pneum. SVP aseptic change-over
0098558
Pneum. SVP aseptic change-over
2117744
Pneum. SVP aseptic change-over
Pneum. SVP aseptic change-over
2127637
Pneum. SVP aseptic change-over
created on/by
en
reviewed on/by
Use
valve
valve
valve
valve
valve
valve
BAA A390-D.03
Select
Version 5.04
22.03.2017
Graf H.
22.03.2017

Advertisement

Table of Contents
loading

Table of Contents