Replacing the seal
II.12.
Replace the seals and friction bearings.
Caution
II.13.
Grease the sealing elements before installation.
Sealing
materials
EPDM
apply a thin layer at the perimeter with a brush
HNBR
apply a thin layer at the perimeter with a brush
FKM
apply a thin layer at the perimeter with a brush
3
P
apply a thin layer at the perimeter with a brush
Caution
Assembling the valve
II.14.
Prior to assembly clean and grease the shafts and sliding surfaces.
II.15.
Fit O-ring (8). into SVP control unit (9).
II.16.
Fit O-rings (6, 7) into the valve disk (5) (take note: chapter 7.7. "Fitting O-ring")
II.17.
Fit diaphragm (4) onto the valve disk (5) - control place and position of the diaphragm.
II.18.
Assemble spindle (3) with valve disk (5) and diaphragm (4) (Tools: Double open ended wrench (wrench size) 17
and 12)
Preload the actuator spring ⇒ control air pressure min. 5 bar (auxiliary assembly air) to connection L
II.19.
Danger
II.20.
Fit the spindle (3) with the valve disk (5) and diaphragm (4) on the spindle of the manual actuator (9)
(Tools: Double open ended wrench (wrench size) 17).
Release the actuator spring ⇒ control air pressure 0 bar (auxiliary assembly air) to connection L
II.21.
II.22.
Disconnect the pneumatic supply line (auxiliary assembly air)
II.23.
Insert the upper part of the valve (1) into the valve housing.
II.24.
Fit the clamp (2) (take note: chapter 7.4. "Mounting the clamp" – tools: torque spanner).
II.25.
Connect electrical cables and pneumatic lines.
24
Copy of original operating instructions
SVP aseptic change-over valve, pneum. operated
DN 010 – 020, OD 0.50" – 0.75"; ISO 008 – 015
Use original spare parts only.
⇒
For original spare parts, refer to the enclosed spare parts list (see
chapter 12 "Spare parts list").
⇒
Perfect functioning of the SVP aseptic change-over valve is only
guaranteed when using original spare parts.
Grease type
PARALIQ GTE 703 (P)
PARALIQ GTE 703 (P)
PARALIQ GTE 703 (P)
PARALIQ GTE 703 (P)
⇒
If a different grease is used
→ corrosion of the sealing elements.
⇒
Do not use mineral greases and animal fat.
⇒
Do not use petroleum grease.
⇒
Prior to assembly grease the inner surface of the diaphragm according to
the lubrication plan.
⇒
Secure the threaded connection GV
⇒
Avoid damage to the spindle (3), diaphragm (4) and the valve disk (5).
⇒
Do not reach into the openings of the SVP control unit.
risk of accidents
limbs may be crushed or severed.
⇒
Secure the threaded connection GV
Operating instructions
diaphragm – O-ring
with adhesive (item no. 0630210).
2
with adhesive (item no. 0630210).
1
created on/by
en
reviewed on/by
BAA A390-D.03
Select
Version 5.04
22.03.2017
Graf H.
22.03.2017