Replacing the seal
II.12.
Replace the seals and friction bearings.
Caution
II.13.
Grease the sealing elements before installation.
Sealing
materials
EPDM
apply a thin layer at the perimeter with a brush
HNBR
apply a thin layer at the perimeter with a brush
FKM
apply a thin layer at the perimeter with a brush
3
P
apply a thin layer at the perimeter with a brush
Caution
Assembling the valve
II.14.
Prior to assembly clean and grease the shafts and sliding surfaces.
II.15.
Fit O-ring (8). into SVP control unit (9).
II.16.
Fit O-rings (6, 7) into the valve disk (5) (take note: chapter 7.7. "Fitting O-ring")
II.17.
Fit diaphragm (4) onto the valve disk (5) - control place and position of the diaphragm.
II.18.
Assemble spindle (3) with valve disk (5) and diaphragm (4) (Tools: Double open ended wrench (wrench size) 17
and 12)
Preload the actuator spring ⇒ control air pressure min. 5 bar (auxiliary assembly air) to connection L
II.19.
Danger
II.20.
Fit the spindle (3) with the valve disk (5) and diaphragm (4) on the spindle of the manual actuator (9)
(Tools: Double open ended wrench (wrench size) 17).
Release the actuator spring ⇒ control air pressure 0 bar (auxiliary assembly air) to connection L
II.21.
II.22.
Disconnect the pneumatic supply line (auxiliary assembly air)
II.23.
Insert the upper part of the valve (1) into the valve housing.
II.24.
Fit the clamp (2) (take note: chapter 7.4. "Mounting the clamp" – tools: torque spanner).
II.25.
Connect electrical cables and pneumatic lines.
24
Copy of original operating instructions
SVP aseptic change-over valve, pneum. operated
DN 010 – 020, OD 0.50" – 0.75"; ISO 008 – 015
Use original spare parts only.
For original spare parts, refer to the enclosed spare parts list (see
chapter 12 "Spare parts list").
Perfect functioning of the SVP aseptic change-over valve is only
guaranteed when using original spare parts.
Grease type
PARALIQ GTE 703 (P)
PARALIQ GTE 703 (P)
PARALIQ GTE 703 (P)
PARALIQ GTE 703 (P)
If a different grease is used
→ corrosion of the sealing elements.
Do not use mineral greases and animal fat.
Do not use petroleum grease.
Prior to assembly grease the inner surface of the diaphragm according to
the lubrication plan.
Secure the threaded connection GV
Avoid damage to the spindle (3), diaphragm (4) and the valve disk (5).
Do not reach into the openings of the SVP control unit.
 risk of accidents
limbs may be crushed or severed.
Secure the threaded connection GV
Operating instructions
diaphragm – O-ring
with adhesive (item no. 0630210).
2
with adhesive (item no. 0630210).
1
created on/by
en
reviewed on/by
BAA A390-D.03
Select
Version 5.04
22.03.2017
Graf H.
22.03.2017