7.8.
Pneum. actuator
7.8.1.
Operating mode air to open - spring to close
Disassembling the actuator
IV.1.
Unscrew the threaded plug (11).
IV.2.
Disconnect the air connection (12) (Tools: Hexagonal screwdriver 3,0 mm)
IV.3.
Unscrew the locking screw (9) and remove the friction bearing (1) and O-rings (2, 10) (Tools: Face spanner,
punch).
IV.4.
Dismantle the closing head support (13) and remove the friction bearings (5, 7) and O-rings (4, 6, 8).
(Tools: drift punch ø5, punch).
Replacing the seal
IV.5.
Replace the seals and friction bearings.
Use original spare parts only.
⇒
⇒
Caution
IV.6.
Prior to assembly clean and grease the shafts and sliding surfaces. Grease the sealing elements before installa-
tion.
Lubrication plan
Apply R =
Skim I =
Assembling the actuator
IV.7.
Fit the friction bearings (5, 7) and O-rings (4, 6, 8) into the closing head support (13).
IV.8.
Screw the closing head support (13) onto the actuator cylinder (3) (Tools: drift punch ø5).
IV.9.
Fit the friction bearing (1) and O-rings (2, 10) in the locking screw (9).
IV.10.
Screw the locking screw (9) onto the actuator cylinder (3) (Tools: Face spanner).
IV.11.
Unscrew the threaded plug (11).
IV.12.
Attach the air connection (12) (Tools: Hexagonal screwdriver 3,0 mm)
28
Copy of original operating instructions
SVP aseptic change-over valve, pneum. operated
DN 010 – 020, OD 0.50" – 0.75"; ISO 008 – 015
For original spare parts, refer to the enclosed spare parts list (see chapter
12 "Spare parts list").
Perfect functioning of the SVP aseptic change-over valve is only guaranteed
when using original spare parts.
RENOLIT SI 410 M - at the periphery using a brush
IFB PW 119 - at the periphery using a brush