Valve On Tank Assembly - Pentair FLECK 4600-SXT Installer Manual

Table of Contents

Advertisement

Installer Manual Fleck 4600 SXT - Maintenance

9.2.10. Valve on tank assembly

No.
A
Lubricate the seals with approved silicone grease.
B
Spin the valve (1) onto the tank (2), ensuring the threads are not cross-threaded.
C
Rotate the valve (1) clockwise and freely, without using force until it comes to a stop.
Note
This stop position is considered point zero.
D
Rotate the valve (1) clockwise from point zero to between ¼ turn and ½ turn.
Caution
Do NOT exceed 27 Nm of torque when installing the valve. Exceeding this limit may damage
the threads and cause failure.
Point 0
78 / 98
Operation
¼ turn
Point 0
½ turn
Ref. MKT-IM-028 / A - 03.07.2018