Svp Aseptic Change-Over Valves With Feedback; Spare Parts - Pentair BAA A390-D.03 Select Operating Instructions Manual

Svp aseptic change-over valve
Table of Contents

Advertisement

Before assembly, clean and grease the sliding surfaces and lubricate the sealing elements.
Seal materials
EPDM
HNBR
FKM
3
P
NBR
Caution
7.2.

SVP aseptic change-over valves with feedback

7.3.

Spare parts

Use original spare parts only.
Caution
BAA A390-D.03
Select
Version 5.04
created on/by
22.03.2017
reviewed on/by
22.03.2017
SVP aseptic change-over valve, pneum. operated
DN 010 – 020, OD 0.50" – 0.75"; ISO 008 – 015
Grease type
PARALIQ GTE 703
PARALIQ GTE 703
PARALIQ GTE 703
PARALIQ GTE 703
RENOLIT SI 410 M
if a different grease is used
→ it may attack seals.
please do not use mineral or animal greases.
Don't use grease based on petroleum.
Don't put fingers into check-back signal.
⇒ A c c i d e n t r i s k .
Danger
Fingers can be crushed or cut off.
For original spare parts, refer to the enclosed spare parts list (see chapter
12 "Spare parts list").
Perfect functioning of the SVP aseptic change-over valve is only guaranteed
when using original spare parts.
Graf H.
Operating instructions
diaphragm – O-ring
en
Copy of original operating instructions
19

Advertisement

Table of Contents
loading

Table of Contents