Control Air - Pentair BAA A390-D.03 Select Operating Instructions Manual

Svp aseptic change-over valve
Table of Contents

Advertisement

3.9.

Control air

Control air pressure
SVP actuator
Process control head IntelliTop
Only use clean and dry compressed air!
Control air quality
As possible oil-free and dry air, neutral gases
Quality classes in accordance with DIN ISO 8573-1(5 μm filter recommended)
Dust content
max. particle size 40 μm, max. particle density 10 mg/m
Quality class 5:
Water content
Quality class 3:
max. pressure dew point -20 °C or min. 10 °C below the lowest ambient temperature
Oil content
Quality class 5:
max. 25 mg/m
Temperature range of compressed air
-10 to +50 °C
12
Copy of original operating instructions
SVP aseptic change-over valve, pneum. operated
DN 010 – 020, OD 0.50" – 0.75"; ISO 008 – 015
min. 6 bar – max. 8 bar
®
2.0
see Operating Manual IntelliTop 2.0
3
Operating instructions
diaphragm – O-ring
3
created on/by
en
reviewed on/by
BAA A390-D.03
Select
Version 5.04
22.03.2017
Graf H.
22.03.2017