Place Of Use, Environment; Lifespan; Atex-Usage; Operation - Pentair BAA A390-D.03 Select Operating Instructions Manual

Svp aseptic change-over valve
Table of Contents

Advertisement

2.7.

Place of use, Environment

⇒ The described SVP aseptic change-over valves are primarily used in breweries, in the food and beverage industry
as well as in the pharmaceutical and cosmetic industry.
⇒ The valves have to be operated in rooms with acid and caustic proof floors.
⇒ The rooms of operation have to be equipped with lights, which enables at all time to read clearly the labels and se-
curity advices.
⇒ The rooms of operation have to be free of dust.
⇒ Do not leave the SVP aseptic change-over valves outdoors.
⇒ Permissible ambient temperature 0° C to +55° C.
⇒ The atmospheric circumstanced (Air temperature, Air moisture and air movement) in the operating rooms shall not
lead to freeze over the moveable parts.
2.8.

Lifespan

The foreseeable lifespan of the SVP aseptic vavles are 15 years..
The maximum switching cycles of the SVP aseptic change-over valves are 500.000.
2.9.

ATEX-usage

The operator of the SVP aseptic change-over valves has to make sure,
Danger
The SVP aseptic change-over valve complies with the EC directives 2014/34/EU.
The applied standards which are used to demonstrate compliance with the Directives are listed in the EC Declaration
of Conformity. This may be requested from Pentair Südmo.
The specifications on the respective rating plate apply to the respective SVP aseptic change-over valve.
Ignition protection type:
ATEX 0123 EX II 2GD IIB TX

2.10. Operation

Danger

2.11. Spare parts

Use original spare parts only.
Caution

2.12. Risk assessment

All safety instructions in these operating instructions result from the risk assessment for the SVP aseptic change-
over valve.
6
Copy of original operating instructions
SVP aseptic change-over valve, pneum. operated
DN 010 – 020, OD 0.50" – 0.75"; ISO 008 – 015
that max. allowable surface temperature gets not exceeded, due to hot me-
dia treatment.
that the ignition temperature gets not exceeded, due to hot media in the
pipework.
that the plant is grounded, where the SVP-aseptic change-over valves get
used.
Never touch the valve or piping system when hot products are in pro-
cessing or during sterilization.
Observe strictly the technical data.
We cannot be held liable for an incorrect use of the valve
For original spare parts, refer to the enclosed spare parts list (see chapter
12 "Spare parts list").
Perfect functioning of the SVP aseptic change-over valve is only guaranteed
when using original spare parts.
Operating instructions
diaphragm – O-ring
created on/by
en
reviewed on/by
BAA A390-D.03
Select
Version 5.04
22.03.2017
Graf H.
22.03.2017