Procedure for bleeding air

Follow steps 1 and 2 to bleed the air.
1. Bleeding air from pump
1. Loosen air bleeder (1) installed to the drain port, and check
that oil oozes out. (Completion of air bleeding)
2. Loosen bleeder plug (2) in the elbow (3) and check that oil
oozes out.
3. After completing the air bleeding operation, tighten the air
bleeder and the plug.
REMARK
If the pump is operated without filling the pump case with
hydraulic oil, abnormal heat will be generated and this may
lead to premature damage of the pump.
2. Starting engine
Start the engine according to "Starting engine (3-112)" keep
running the engine at low idling for 10 minutes, and carry out
the following procedure.
3. Bleeding air from cylinders
1. Run the engine at low idling, for 5 minutes after engine start.
Extend and retract each cylinder 4 - 5 times without operat-
ing it to the end of its stroke. (Stop approx. 100 mm before
the end of the stroke)
2. Next alter engine speed to Max., and operate again as step
1.
3. After this, operate each cylinder 4 - 5 times to the end of its
stroke to completely bleed the air.
NOTE
If, at first, the engine is run at high speed or the cylinder is
operated to the end of its stroke, the air inside the cylinder
may cause damage to the piston packing or other parts.
PW180-7E0 – VEAM400102
4.11 Maintenance procedure
Every 5000 hours service
1
4-105

Advertisement