Maintenance
4. Install cover (6) as follows.
Align cover (6) with the element.
Hook the tip of hook (2) to the protruding part of the air
cleaner body and lock it in position.
Install cover (6) so that the evacuator is facing the
ground.
When cover (6) is installed, check that the clearance
between the air cleaner body and cover (6) is not too
large.
If it is too large, install again.
PW180-7E0 – VEAM400102
4.11 Maintenance procedure
Top
GL
Evacuator valve
When required
2
GK018385
6
2
GK018377