4.11 Maintenance procedure
When required
Removal
WARNING
Hot, scalding coolant can spray out if the radiator cap is
removed suddenly. Relieve system pressure by slowly turn-
ing the cap to the first notch or lifting the safety lever
(option). Remove the cap only after the pressure is relieved.
Use extreme caution when adding coolant to the radiator to
avoid being burned. Wear gloves and goggles and keep face
away from the filler neck.
To remove the cap, turn the cap to the left, or counterclockwise
up to the safety stop until the cap is free to be removed.
Installation
When installing the cap, the gasket and contacting surfaces
must be clean. Turn the cap to the right, or clockwise until snug.