3-20.4 Link Events

This chapter introduces the user to inspect the current Link OAM Link Event configurations,
and change them as well. The Link OAM Link Event status relate to the currently selected
stack unit, as reflected by the page header. The left pane displays the Event status for the
Local OAM unit while the right pane displays the status for the Peer for the respective port.
Web Interface
To display the Link Events in the web interface:
1. Click Configuration, 802.3ah OAM then Link Events.
2. Scroll to select which port you want to monitor the Link Events.
3. Evoke auto-refresh to update the detailed Link Events data.
4. Click the Refresh to update the Link Events.
.
Figure 3-20.4: The detailed Link OAM Port status
Parameter description:
Port :
You can scroll to select which port you want to monitor detailed Link OAM events. It shows
the switch port number.
Frame Error Event Timestamp :
The field shows this two-octet field indicates the time reference when the event was
generated, in terms of 100 ms intervals.
Frame Error Event Window :
The field shows this two-octet field indicates the duration of the period in terms of 100 ms
intervals. 1) The default value is one second. 2) The lower bound is one second. 3) The
upper bound is one minute.
Frame Error Event threshold :
The field shows this four-octet field indicates the number of detected errored frames in the
period is required to be equal to or greater than in order for the event to be generated. 1)
The default value is one frame error. 2) The lower bound is zero frame errors. 3) The upper
bound is unspecified.
Frame Errors :
The field shows this four-octet field indicates the number of detected errored frames in the
period.