ZyXEL Communications XGS3600 Series Manual page 88

Gbe l2 switch with 10g gbe uplink
Table of Contents

Advertisement

Advanced Settings
Edge Port BPDU Filtering :
Control whether a port explicitly configured as Edge will transmit and receive
BPDUs.
Edge Port BPDU Guard :
Control whether a port explicitly configured as Edge will disable itself upon
reception of a BPDU. The port will enter the error-disabled state, and will be
removed from the active topology.
Port Error Recovery :
Control whether a port in the error-disabled state automatically will be enabled
after a certain time. If recovery is not enabled, ports have to be disabled and
re-enabled for normal STP operation. The condition is also cleared by a system
reboot.
Port Error Recovery Timeout :
The time to pass before a port in the error-disabled state can be enabled. Valid
values are between 30 and 86400 seconds (24 hours).
Buttons
Apply – Click to apply changes.
Reset- Click to undo any changes made locally and revert to previously saved
values.
XGS3600 Series User's Guide
81

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xgs3600-26fXgs3600-28Xgs3600-28f

Table of Contents