R-IN32M3-CL User's Manual
6.1.3
CC-Link IE Field (Intelligent Device Station) Bus Size Control Register (CIEBSC)
The CIEBSC register is for setting the data bus width to access the CC-Link IE field (intelligent device station). When
using the CC-Link IE field (intelligent device station), set the bits of this register to 0000 5555H.
•
Access
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
CIEBSC
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0
0
0
0
0
R/W
Bit Position
Bit Name
15 to 0
CIEBSC15-0 These bits should be set to 5555H.
6.1.4
CC-Link IE Field (Intelligent Device Station) Bus Bridge Control Register
(CIESMC)
The CIESMC register is used for access control. When using the CC-Link IE field (intelligent device station), be sure to
set the bits of this register to 0000 1151H.
• Access
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
CIESMC
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0
0
0
0
0
R/W
Bit Position
Bit Name
15 to 0
CIESMC15-0
R18UZ0005EJ0400
Dec. 28, 2018
This register can be read and written in 32-bit units.
0
0
0
0
0
0
0
0
0
This register can be read and written in 32-bit units.
0
0
0
0
0
0
0
0
0
These bits should be set to 1151H.
6. CC-Link IE Field (Intelligent Device Station) Function
0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
0
Description
0 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
0
Description
8
7
6
5
4
3
2
1
0
8
7
6
5
4
3
2
1
0
Page 55 of 104
Address
400A 4004H
Initial value
0000 5555H
Address
400A 4008H
Initial value
0000 FFFFH