Control; Do Config And Manual - Danfoss AK-CC55 Compact User Manual

Case/room controller (eev)
Hide thumbs Also See for AK-CC55 Compact:
Table of Contents

Advertisement

AK-CC55 Compact
Function
Values
Dewpoint min limit
Dewpoint max limit
Rail heat min ON cycle
Door restart inj. delay
Fan at forced closing
0=OFF, 1=ON, 2=OFF and
suppress defrost, 3=ON
and suppress defrost
Light at Main switch OFF
0=OFF, 1=Normal ctrl.
(1)
(1)
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.

Control

Table 20: Control
Function
Values
Alarm relay priority
0=Not used, 1=High Prior-
ity, 2=Medium priority,
3=All
Blinds max open time
Fan stop at blinds closing
Rail heat PWM - Period
time
Refrigerant factor K1
Refrigerant factor K2
Refrigerant factor K3
Max superheat liquid ctrl.
Min superheat liquid ctrl
Access code 1
Display keyboard lock
0=None, 1=Local, 2=Net-
work
(1)
(1)
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.

DO config and manual

Table 21: DO config and manual
Function
Values
DO2 Configuration
0=None, 1=Fans, 2=Fan
ECO, 3=Defrost, 4=Rail
heat, 5=Alarm, 6=Light,
7=Blinds, 8=Compressor/
LLSV, 9=Compressor 2,
10=Air heater
DO3 Configuration
0=None, 1=Fans, 2=Fan
ECO, 3=Defrost, 4=Rail
heat, 5=Alarm, 6=Light,
7=Blinds, 8=Compressor/
LLSV, 9=Compressor 2,
10=Air heater
DO4 Configuration
0=None, 1=Fans, 2=Fan
ECO, 3=Defrost, 4=Rail
heat, 5=Alarm, 6=Light,
7=Blinds, 8=Compressor/
LLSV, 9=Compressor 2,
10=Air heater
AO1 Configuration
0=None, 1=Rail heat PWM 1-3
EEV override A
Compressor 1 - override
0=MAN OFF, 1=MAN ON
Fan - override
0=MAN OFF, 1=MAN ON
Defrost A - override
0=MAN OFF, 1=MAN ON
Rail heat - override
0=MAN OFF, 1=MAN ON
Alarm relay - override
0=MAN OFF, 1=MAN ON
Light - override
0=MAN OFF, 1=MAN ON
Compressor 2 - override
0=MAN OFF, 1=MAN ON
© Danfoss | Climate Solutions | 2022.08
R-W
Code
1
2
3
4
1-2
o86
*
*
*
*
1-2
o87
*
*
*
*
1-2
o88
*
*
*
*
1-2
o89
*
*
*
*
1-2
o90
*
*
*
*
1-2
o98
*
*
R-W
Code
1
2
3
4
1-2
P41
*
*
1-2
P60
*
1-2
P65
*
*
1-2
P82
*
*
*
*
1-3
(1)
P83
1-3
P84
(1)
1-3
P85
(1)
1-2
P86
1-2
P87
1-1
P88
*
*
*
*
1-2
P89
*
*
*
*
R-W
Code
1
2
3
4
1-3
q02
*
(1)
1-3
q03
*
(1)
1-3
q04
*
(1)
q09
*
*
*
*
(1)
1-2
(2)
q11
1-2
q12
*
*
*
*
(2)
1-2
q13
*
*
*
*
(2)
1-2
q14
*
*
*
*
(2)
1-2
(2)
q15
*
*
1-2
q16
*
*
(2)
1-2
q17
*
*
(2)
1-2
q19
*
(2)
5
6
7
8
9
Min. value Max. value Fact. value
*
*
*
*
*
-10.0 °C
*
*
*
*
*
o86
*
*
*
*
*
0 %
*
*
*
*
*
0 min
*
*
*
*
*
0
*
*
0
5
6
7
8
9
Min. value Max. value Fact. value
*
*
0
*
0 min
*
*
0 s
*
*
*
*
*
4 s
*
*
*
*
*
-999
*
*
*
*
*
-999
*
*
*
*
*
-999
*
*
*
*
*
P87
*
*
*
*
*
0.0 °C
*
*
*
*
*
0
*
*
*
*
*
0
5
6
7
8
9
Min. value Max. value Fact. value
*
0
*
0
*
0
*
*
*
*
*
0
*
*
*
*
*
0 %
*
*
0
*
*
*
*
*
0
*
*
*
*
*
0
*
*
0
*
*
0
*
*
0
*
0
BC365212986197en-000201 | 41
o87
8.0 °C
50.0 °C
17.0 °C
100 %
30%
240 min
30 min
3
1
1
0
3
2
60 min
5 min
300 s
0 s
60 s
10 s
999
300
999
300
999
300
20.0 °C
3.0 °C
P86
1.0 °C
999
0
2
0
10
6
10
8
10
9
1
0
100 %
0%
1
0
1
0
1
0
1
0
1
0
1
0
1
0