Sign In
Upload
Download
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Du Pont Manuals
Laboratory Equipment
SORVALL RC-5
Service manual
Du Pont SORVALL RC-5 Service Manual page 163
Automatic superspeed refrigerated centrifuges
Hide thumbs
1
2
3
4
5
6
Table Of Contents
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
page
of
245
Go
/
245
Bookmarks
Advertisement
Son/all®
CentrifugesMaintenance
&
Repairb.
Installation1.
Install
the
condensing
assembly
in
the
centrifuge
through
the
rear
of
the
frame.2.
Secure
the
condensing
assembly
base
to
the
frame
with
the
three
socket
headscrews.3.
Reconnect
the
high
pressure
line
and
the
suction
line
to
the
refrigeration
assembly,at
the
proper
locations.4.
Connect
the
electrical
leads
to
terminals
7,
8,
and
9
on
TB201.5.
Charge
the
system
in
accordance
with
paragraph
6-16.6.
Replace
all
cabinet
panels.6-14.
Electronic
Controls
Replacementa.
Resistance
Temperature
Detector1.
Removala.
Set
main
circuit
breaker
to
OFF.b.
Unplug
the
power
cord
from
socket.c.
Remove
the
cabinet
rear
panel.d.
Tag.
then
disconnect
detector
wires
at
TB306.e.
Pry
out
resistance
temperature
detector
cover
at
the
bottom
of
the
evaporator.then
remove
the
detector.Figure
6-42.Removing
Wires
jrom
TerminalBoard
TB306Figure
6-43.Removing
Temperature
Detectorfrom
the
Chamber
^.^5
Previous
Page
Next
Page
1
...
162
163
164
165
Show Quick Links
Quick Links:
Table of Contents
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Related Manuals for Du Pont SORVALL RC-5
Laboratory Equipment Du Pont SORVALL RT6000B Operating Instructions Manual
Tabletop centrifuges (28 pages)
Laboratory Equipment Du Pont Sorvall RC-5B Plus Service Manual
(102 pages)
Laboratory Equipment Du Pont SORVALL SUPRASPEED RC-28S Operating Instructions Manual
(71 pages)
Related Products for Du Pont SORVALL RC-5
Du Pont SORVALL RT6000B
Du Pont Sorvall RC-5B Plus
Du Pont SORVALL SUPRASPEED RC-28S
Du Pont SORVALL T6000B
This manual is also suitable for:
Sorvall rc-5b
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL