Sign In
Upload
Download
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Du Pont Manuals
Laboratory Equipment
SORVALL RC-5
Service manual
Du Pont SORVALL RC-5 Service Manual page 161
Automatic superspeed refrigerated centrifuges
Hide thumbs
1
2
3
4
5
6
Table Of Contents
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
page
of
245
Go
/
245
Bookmarks
Advertisement
Sorvall®
Centrifuges
Maintenance
&
Repairb.
Installation1.
Install
the
new
evaporator
assembly
In
the
chamber.2.
Place
the
urethane
seal
on
top
of
the
lock
foam
insulating
material.3.
Place
the
wooden
deck
with
plastic
ring
and
rubber
seal
on
the
cooling
chamber.Adjust
the
evaporator
inside
the
chamber
to
properly
align
the
rubber
seal
andevaporator
while
pressing
the
rubber
seal
ring
onto
the
evaporator.4.
Place
the
aluminum
plates
in
position.
Reconnect
the
wires
to
the
latching
mecha¬nism
and
install
the
KSB
tubes.5.
Align
each
aluminum
plate
with
the
scribe
lines
on
the
frame
and
secure
them
inposition.6.
Install
the
front
and
rear
rails.7.
Install
the
deck
and
console.8.
Connect
the
drain
tube.9.
Install
and
connect
the
resistance
temperature
detector
(paragraph
6-14).10.
Install
the
gyro
action
drive
assembly
(paragraph
6-4).11.
Reconnect
the
main
power
cord
and
main
power
plug.12.
Reconnect
refrigeration
lines
and
recharge
the
system.
Then
check
for
leaks
(para¬graph
6-16).6-13.
Condensing
Assembly
Replacementa.
Removal1.
Set
main
circuit
breaker
to
OFF.2.
Unplug
the
power
cord
from
socket.3.
Remove
all
cabinet
panels.4.
Disconnect
compressor
leads
at
terminals
7,
8,
and
9
on
TB201.5.
Remove
refrigerant
from
the
system
(see
paragraph
6-16).6.
Using
an
open
end
wrench
(1-3/8
in),
disconnect
the
suction
line
from
compressor.7.
Using
an
open
end
wrench
(25/32
in),
disconnect
the
high
pressure
line
from
theservice
valve.6-23
Previous
Page
Next
Page
1
...
160
161
162
163
Show Quick Links
Quick Links:
Table of Contents
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Related Manuals for Du Pont SORVALL RC-5
Laboratory Equipment Du Pont SORVALL RT6000B Operating Instructions Manual
Tabletop centrifuges (28 pages)
Laboratory Equipment Du Pont Sorvall RC-5B Plus Service Manual
(102 pages)
Laboratory Equipment Du Pont SORVALL SUPRASPEED RC-28S Operating Instructions Manual
(71 pages)
Related Products for Du Pont SORVALL RC-5
Du Pont SORVALL RT6000B
Du Pont Sorvall RC-5B Plus
Du Pont SORVALL SUPRASPEED RC-28S
Du Pont SORVALL T6000B
This manual is also suitable for:
Sorvall rc-5b
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL