Local ventilation
Observe the following instructions when installing an extractor hood:
VDI Guideline 2052, NFPA 96 and the guidelines of the local building com-
n
mission for extractor hoods.
The extractor hood must extend 300-500 mm [12 – 20 inch] beyond the
n
front of the unit.
When using a VarioSmoker, install the device under an externally ventilated
n
extractor hood.
Install a grease filter in the overhanging area of the extractor hood.
n
Extractor hood
An extractor hood (also for retrofitting) is available for the units. To install the
extractor hood, follow the installation instructions supplied with the extractor
hood.
80.06.083_iCombiPro-iCombiClassic_IM_en-US
5 | Setup
43 / 96