Procedure D2: Protective Cover Assembly - Sames inocoat Inogun A Instruction Manual

Table of Contents

Advertisement

6.4.5. Procedure D2: Protective cover assembly

Disassembly:
• Using a long cross-head screwdriver, loosen the 2 PT
40x 30 screws.
• Pull to remove the protective cover assembly.
• Check the condition of the O-rings, replace if
necessary.
• Remove the electrode blowing duct, check its
condition, replace if necessary.
Reassembly:
For the reassembly of the protective cover, it is imperative that the powder tube has been
removed beforehand.
• Proceed in the reverse order: position the protective cover on the gun,
• Put the 2 PT 40x 30 screws in place and tighten to 75 cN.m.
38
DRT7133
D - 2023/01