1.7. Important recommendations

1.7.1. Ventilation

Do not start the powder application with the Inogun A projector until the spray booth ventilation system is switched
on. If the ventilation is switched off, toxic substances or dust may remain in the spray booth and cause a risk of fire,
poisoning or irritation.

1.7.2. O-ring seals

Use the seals recommended in this manual.

1.7.3. Safety devices

When installing the projector, safety devices must be provided.
• Detection of control system faults.
• Detection of high voltage surges associated with the Sames HV generator.
• Detection of air pressure drops.
• Detection of ventilation failure.
• Detection of variations in ventilation flow rates.
• Detection of fire.
Failure to install safety devices could result in a risk of fire, expose the personnel to serious injury and
damage the equipment.
The electrostatic projection systems must be equipped with an automatic fire extinguishing
system (according to § 5.2.5 in standard EN 50177).

1.7.4. Mechanical collision

The guarantee does not cover damage resulting from the operating environment (for example: collision with the
robot).

1.7.5. Ambient temperature

The atomizer is designed to normally operate at an ambient temperature comprised between 0°C and + 40°C.