5.2.5. Installation of a 60° or 90° nozzle adapter
The Inogun A gun can be equipped with optional 60° and 90° nozzle adapters for flat spray and round spray
(see § 8.12 page
73).
• Switch off high voltage,
• Step 1: Manually unscrew the nozzle nut (1).
• Step 2: Remove the electrode support assembly (3)
and its deflector (2) flat spray or round spray.
• Step 3: Screw the nut(4) of the 60° or 90° nozzle
adapter onto the barrel of the Inogun A.
• Step 4: Install the electrode support assembly (3) and
its deflector (2) flat spray or round spray on the 60° or
90° nozzle adapter.
• Step 5: Screw the nozzle nut (1) onto the adapter by
hand.
• Restart the high voltage supply.