Sames inocoat Inogun A Instruction Manual page 11

Table of Contents

Advertisement

This equipment must only be used in powdering locations according to standard EN 50177 (§
5.4 and 5.7) and EN 16985. The equipment has to be used only within ventilated in order to
reduce risks for the health of the operators, fire or explosion. The efficiency of the extraction
ventilation system has to be daily checked.
Within explosive atmospheres produced by the spraying process, only appropriate explosion-
proof electrical equipment has to be used.
1 The operator must wear shoes according to standard EN ISO 20344 and the insulation resistance measured
must not exceed 100 M
2 The protective clothes, including gloves, must conform to standard EN 1149-5 and the insulation resistance
measured must not exceed 100 M
3 Using individual protection equipment will limit the risks of contact and/or inhalation of toxic product, gas,
vapours, fog or dusts that can be produced while using the equipment. The user has to follow the coating
product manufacturer's recommendations.
4 Contact or inhalation of the products used with this equipment may be dangerous for personnel (see: safety
data sheets for the products used). The pressure coating material or compressed air must not be directed at
people or animals.
5 The parts to be painted must have a resistance to earth less than or equal to 1 M
at least 500V or 1000V) (§5.7.3 in standard EN 50177). This must be checked regularly.
6 All conductive structures such as floors, powder spray station walls, ceilings, barriers, barriers, parts to be
painted, powder dispensing tank placed in or near the work area and the ground terminal of the electro-
pneumatic control module must be electrically connected to the grounding system for protecting the power
supply. Finally, and for the same reasons, it will be necessary, in the spraying area, to have an antistatic floor
such as bare concrete, metal grating, etc...
7 Switch off the power supply to the Inocontroller or Inobox before connecting the Inogun A projector. Before
disconnecting the projector, disconnect the power supply to the Inocontroller or Inobox (otherwise, a
malfunction may occur).
8 IIt is essential to properly ventilate the spray booths to avoid any powder output and to ensure a powder
concentration below the lower explosive limit (LEL). The associated equipment must be placed outside the
hazardous areas and its commissioning must be controlled by the operation of the cabin suction fan.
9 Powder spraying must be carried out in front of a ventilated station provided for this purpose. The activation of
the Inocontroller must be controlled by the operation of the ventilation system. The correct operation of the
drive must be checked once a week.
10 The ambient operating temperature must be between 0 and 40°C.
11 The electrostatic powder spraying equipment must be maintained regularly in accordance with the indications
and instructions given by Sames. Repairs must be carried out in strict accordance with these instructions.
12The electrostatic powder spraying equipment must be maintained regularly in accordance with the indications
and instructions given by Sames. Repairs must be carried out in strict accordance with these instructions.
13 Before cleaning the projectors or doing any other work in the spray area, the power supply to the high-voltage
generator must be disconnected, protected against restarting and the HV circuit protected. (projector)
discharged to ground.
Cleaning must be carried out in mechanically ventilated areas.
Ω
.
.
Ω
11
DRT7133
D - 2023/01
Ω
(measurement voltage of
Member of Exel group

Advertisement

Table of Contents
loading

Table of Contents