6.4.7. Procedure D2: Replacement of low voltage cable

• Step 1: Push the 2 bolts so that the powder hose can
be unlocked and removed.
• Step 2: Remove the air hose.
• Step 3: Loosen the 3 screws.
• Step 4: Remove the base plate from the handle and
disconnect the blue connector from the control box.