Regulatory Tests To Be Carried Out On The Equipment According To Standard; Important Recommendations; Ventilation; O-Ring Seals - Sames Inocoat Inogun M Instruction Manual

Powder spray gun
Table of Contents

Advertisement

14The electrostatic powder spraying equipment should only be operated if it is in perfect condition. Damaged
equipment must be removed from service immediately and repaired.
15Before cleaning the projectors or doing any other work in the spray area, the power supply to the high-voltage
generator must be disconnected, protected against restarting and the HV circuit protected. (projector)
discharged to ground.
Cleaning must be carried out in mechanically ventilated areas.
16Inside the booth it is forbidden to use naked flames, glowing objects or devices likely to produce sparks.
It is also forbidden to store flammable products, or recipients that have contained them, in the vicinity of the
booth.
The surrounding area must be kept clear and clean.
17In the explosive zone, it is forbidden to use non-certified electrical or non-electrical equipment such as
electrical extension cords, multi-sockets, switches, etc.
A warning sign in a language understood by the operator, summarizing the safety rules described above, must be
prominently displayed in the vicinity of the powder spray station.
1.6. Regulatory tests to be carried out on the equipment according to standard EN 50050-2
The tests must be carried out on the spraying equipment. The tests must be carried out by competent personnel
and include the tests described below (see § 6.2.3 table 1 in standard EN 50050-2).
Grounding measures
Forced ventilation interlock and manual electrostatic spraying
equipment
Checking manual electrostatic spraying equipment for damage
(*) Intervals depend on operating and local conditions.

1.7. Important recommendations

1.7.1. Ventilation

Do not start the powder application with the Inogun M spray gun until the spray booth ventilation system is
switched on. If the ventilation is switched off, toxic substances or dust may remain in the spray booth and cause a
risk of fire, poisoning or irritation.

1.7.2. O-ring seals

Use the seals recommended in this manual.

1.7.3. Ambient temperature

The spray gun is designed to normally operate at an ambient temperature comprised between 0°C and + 40°C.
The storage temperature must never exceed +60°C.
Type of test
Weekly
Annual
Weekly
12
DRT7132
D - 2022 /09
Requirements
Member of Exel group