5.12
Step 5: Finishing the transmitter connection
Connection check-up
1. Check individual wire installation by tugging firmly.
2. Firmly tighten cable glands and insert blanking plugs in unused cable entries.
3. Remove o-ring from lid.
4. Reinstate lid and screw in until mechanical stop. Wind back lid by one turn.
5. Mount o-ring by pulling it over the lid and tighten lid cover until you feel friction from the o-
6. Reinstate and tighten lid lock screw where supplied.
7. Ensure that moisture does not penetrate to inside of electronics housing by creating a
NOTICE
Loss of degree of protection
Damage to device if the enclosure is open or not properly closed. The degree of protection
specified on the nameplate or in "Technical data" (Page 169) is no longer guaranteed.
Make sure that the device is securely closed.
SITRANS FC430 with HART
Operating Instructions, 03/2012, A5E03361511-01
ring on both sides. Wind lid by one quarter of a turn to seal on the o-ring.
drip loop (bend cables downward) immediately before cable glands.
5.12 Step 5: Finishing the transmitter connection
Connecting
67