4. Gobo/Color and Lamp

4.1 Gobo/Color

CAUTION: Never unscrew the screws of the rotating gobo as the ball bearing will otherwise be
opened!

4.2 Light Source

Philips MSD Platinum 12R LL
Because of its high internal pressure, there might be a risk that the Discharge lamp would
explode during operation. The lamp emits intense UV radiation which is harmful to the
eyes and skin. The high luminance of the arc can cause severe damage to the retina if you
take a close look at the lamp.
To protect the lamp, always turn off the lamp first (via control panel or DMX controller)
and let the unit run at least five minutes to cool down before switching off the mains
supply. Never handle the lamp or luminary when it is hot.
Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured
alcohol and wipe it with a lint free cloth before installation.
The lamp generates UV radiation. Never operate the lamp without appropriate shielding.
When lighting up, the lamp operates at high pressure and there is a slight risk of arc tube
rupture. The risk increases with age, temperature and improper handling of the lamp. Do not
use the lamp longer than its lifespan.
Make sure the lamp is located in the center of the reflector for the best projection.
Install the gobos with the device switched off only.
Unplug from mains before changing gobos!
DANGER!
7C