9. Focus Reset Fail
Check if the position of the focus mounting magnetic steel falls off or is damaged.
Check if there are other interference items in the focus operating range.
Check if the focus Hall elements is damaged.
Check if the focus Hall elements is in poor contact with the lead of the PCB board or disconnected.
Check if the focus motor is damaged.
Check if there is any damage to the circuit of the focus motor drive board.
10. Lamp Hot Power Off
Check if the temperature switch of the lamp is off.
Check if the fans are still running properly.
11. LampFan1/2/3 cannot start
Check if lampfan1/2/3 is not running
12. LampFan1/2/3 cannot stop
Check if the lampfan1/2/3 is still running when the lamp turns off for one minute.
13. BaseFan1/2 cannot start
Check if basefan1/2 is not running
14. BaseFan1/2 cannot stop
Check if the basefan1/2 is still running when the lamp turns off for one minute.

8. Troubleshooting

Following are a few common problems that may occur during operation. Here are some suggestions
for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connect power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED to see if it can be light up or not.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if they are linked properly.
2. If the DMX LED is on and no response to the channel, check the address settings and DMX
polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit
26C