  • Page 2: Table Of Contents

    CONTENTS 1. Safety Instructions ....................2 2. Technical Specifications ..................4 3. Description ......................4 3.1 Control Panel ....................4 4. How To Set The Unit ....................5 4.1 Main Function ....................5 4.2 Home Position Adjustment ................12 5. Control By Universal DMX Controller ..............12 5.1 Connection ....................
  • Page 3: Safety Instructions

    1. Safety Instructions Please read the instruction carefully which includes important information about the installation, usage and maintenance. WARNING Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction manual. Important: Damages caused by the disregard of this user manual are not subject to warranty.
  • Page 4 the mains power immediately. DO NOT operate in dirty or dusty environment, do clean fixtures regularly.  DO NOT touch any wire during operation as there might be a hazard of electric shock.  Avoid power wires together twist other cables. ...
  • Page 5: Technical Specifications

    2. Technical Specifications ◇ Outstanding color mixing effect ◇ LCD display for easy navigation ◇ DMX Channel:166/206/22+144/21 Channel ◇ Control Mode: DMX512,Art-Net ◇ Power Voltage: AC 100V~240V, 50/60Hz ◇ Power Consumption: 580W ◇ Light Source: 36(6X6) x 15W RGBW LED 49(7X7) x 0.06W CW LED ◇...
  • Page 6: How To Set The Unit

    POWER Power on DMX input present 2. Display: To show the various menus and the selected function. 3. Button: MENU To enter into move backward or leave the menu To go backward to move up in the menu DOWN To go to move down in the menu ENTER To perform the desired functions 4.
  • Page 7 166 СH 206 СH 22+144 СH 21 СH IP Address Ethernet IP Setup DMX Setting Subnet Mask Subnet Art Net Port Setup Universe Hold Blackout Fast Smooth Fixture Setting 1~10 1~30 Display Setting No/Yes English/Chinese 0 255 0 255 0 255 Manual Mode 0 255 0 255...
  • Page 8 DMX Setting To select DMX Settings press the ENTER button to confirm, use the UP/DOWN button to select Channel Mode, Art-Net Setup or Port A DMX Address. Channel Mode To select Channel Mode, press the ENTER button to confirm. Use the UP/DOWN button to select 166 CH, 206 CH, 22+144CH or 21 CH channels mode, press the ENTER button to store.
  • Page 9 Pan Inverse To select Pan Inverse, press the ENTER button to confirm. Use the UP/DOWN button to select No (normal) or Yes (pan inverse), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode. Tilt Inverse To select Tilt Inverse, press the ENTER button to confirm.
  • Page 10 Language Select Language, press the ENTER button to confirm, present mode will blink on the display, use the UP/DOWN button to select English or Chinese. Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode. Manual Mode Enter menu mode, select Manual Mode, press the ENTER button to confirm, use the UP/DOWN button to select Pan Position, Tilt Position, Pan Infinity, Tilt Infinity , M6X6 Dimmer, M6X6...
  • Page 11 Select M6X6 Strobe, press the ENTER button to confirm, present mode will blink on the display, use the UP/DOWN button to adjust value from 0 to 255, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode. M6X6 Effect Select M6X6 Effect, press the ENTER button to confirm, present mode will blink on the display, use the UP/DOWN button to adjust value from 0 to 255, press the ENTER button to store.
  • Page 12 Automatic Test Select Automatic Test, press the ENTER button to confirm, the unit will run built-in programs to automatically test pan, tilt, dimmer, pattern, and so on. Press the MENU button back to the last menu or exit menu mode after auto test. Fixture Information Enter menu mode, select Fixture Information, press the ENTER button to confirm, use the UP/DOWN button to select LED Temperatue, Power on hours, LED on hours or Sofatware...
  • Page 13: Home Position Adjustment

    4.2 Home Position Adjustment Press the MENU button into menu mode, then press the ENTER button for about 3 seconds into offset mode to adjust the home position. Select the function by the ENTER button. Use the UP/DOWN button to choose the submenu, press the ENTER button to store and automatically return to the last menu.
  • Page 14: Address Setting

    last unit. 2. Connect the unit together in a “daisy chain” by XLR plug cable from the output of the unit to the input of the next unit. The cable cannot be branched or split to a “Y” cable. DMX 512 is a very high-speed signal.
  • Page 15: Dmx 512 Configuration

    5.3 DMX 512 Configuration Please refer to below configurations to control the fixtures Attentions: 1. The unit will maintain the last condition until reset if you cut-off the DMX signal. 2. For the channel Function, keep the value for about 5 seconds, then the corresponding function will take into effect.
  • Page 16 DIMMER 000-255 0%  100% 000-255 DIMMER FINE STROBE 000-007 Close 008-015 Open 016-131 Strobe, slow to fast 132-139 Open 140-181 Fast close slow open 182-189 Open 190-231 Fast open slow close 232-239 Open 240-247 Random Strobe 248-255 Open 000-255 0% ...
  • Page 17 096-135 Number 1 to 9 (see channel 18-2) 136-175 Letter A to Z (see channel 18-3) 176-215 Letter a to z (see channel 18-4) 216-255 Blackout RGBW MARCO EFFECT 000-007 No function 008-015 Effect 01 016-023 Effect 02 024-031 Effect 03 032-039 Effect 04 040-047...
  • Page 18 208-215 Effect 26 216-223 Effect 27 224-231 Effect 28 232-239 Effect 29 240-247 Effect 30 248-255 Effect 31 RGBW NUMBER 000-025 No function 026-048 Number – 0 049-071 Number – 1 072-094 Number – 2 095-117 Number – 3 18-2 118-140 Number –...
  • Page 19 121-129 Letter – L 130-138 Letter – M 139-147 Letter – N 148-156 Letter – O 157-165 Letter – P 166-174 Letter – Q 175-183 Letter – R 184-192 Letter – S 193-201 Letter – T 202-210 Letter – U 211-219 Letter –...
  • Page 20 157-165 Letter – p 166-174 Letter – q 175-183 Letter – r 184-192 Letter – s 193-201 Letter – t 202-210 Letter – u 211-219 Letter – v 220-228 Letter – w 229-237 Letter – x 238-246 Letter – y 247-255 Letter –...
  • Page 21 120-131 Patent 11 132-143 Patent 12 144-155 Patent 13 156-167 Patent 14 168-179 Patent 15 180-191 Patent 16 192-203 Patent 17 204-215 Patent 18 216-227 Patent 19 228-239 Patent 20 240-255 Close STAR DIMMER STAR STROBE 000-012 Open 013-025 Close 026-076 Slow ...
  • Page 22 PAN/TILT SPEED 000-255 Fast to Slow Pan Infinity Pan Position 000-127 CW Infinity 128-191 192-255 CCW Infinity Tilt Infinity 000-127 Tilt Position 128-191 CW Infinity 192-255 CCW Infinity FUNCTION No function 000-049 Enable blackout while P/T moving 050-059 Disable blackout while P/T moving 060-069 All reset 070-079 080-255...
  • Page 23 STAR DIMMER STAR STROBE 000-012 Open 013-025 Close 026-076 Slow  Fast 077-127 Slow Open Fast Close 128-178 Fast Open Slow Close 179-242 Random 243-255 Open 158-206 49 Star Pixel 22+144 Channels (Mode 3): CHANNEL VALUE FUNCTION 1(Port A) 000-255 0 °...
  • Page 24 000-049 No function 050-059 Enable blackout while P/T moving 060-069 Disable blackout while P/T moving 070-079 All reset 080-255 No function DIMMER 000-255 0%  100% 000-255 DIMMER FINE STROBE 000-007 Close 008-015 Open 016-131 Strobe, slow to fast 132-139 Open 140-181 Fast close slow open...
  • Page 25 192-255 Mix Input RGBW EFFECT MODE 000-014 Blackout 015-047 Full On 048-095 Effect (see channel 18-1) 096-135 Number 1 to 9 (see channel 18-2) 136-175 Letter A to Z (see channel 18-3) 176-215 Letter a to z (see channel 18-4) 216-255 Blackout RGBW MARCO EFFECT...
  • Page 26 168-175 Effect 21 176-183 Effect 22 184-191 Effect 23 192-199 Effect 24 200-207 Effect 25 208-215 Effect 26 216-223 Effect 27 224-231 Effect 28 232-239 Effect 29 240-247 Effect 30 248-255 Effect 31 RGBW NUMBER 000-025 No function 026-048 Number – 0 049-071 Number –...
  • Page 27 076-084 Letter – G 085-093 Letter – H 094-102 Letter – I 103-111 Letter – J 112-120 Letter – K 121-129 Letter – L 130-138 Letter – M 139-147 Letter – N 148-156 Letter – O 157-165 Letter – P 166-174 Letter –...
  • Page 28 112-120 Letter – k 121-129 Letter – l 130-138 Letter – m 139-147 Letter – n 148-156 Letter – o 157-165 Letter – p 166-174 Letter – q 175-183 Letter – r 184-192 Letter – s 193-201 Letter – t 202-210 Letter –...
  • Page 29 060-071 Patent 6 072-083 Patent 7 084-095 Patent 8 096-107 Patent 9 108-119 Patent 10 120-131 Patent 11 132-143 Patent 12 144-155 Patent 13 156-167 Patent 14 168-179 Patent 15 180-191 Patent 16 192-203 Patent 17 204-215 Patent 18 216-227 Patent 19 228-239 Patent 20...
  • Page 30 000-255 PAN FINE TILT 000-255 0 °  450° 000-255 TILT FINE PAN/TILT SPEED 000-255 Fast to Slow Pan Infinity Pan Position 000-127 CW Infinity 128-191 192-255 CCW Infinity Tilt Infinity 000-127 Tilt Position 128-191 CW Infinity 192-255 CCW Infinity FUNCTION No function 000-049...
  • Page 31 232-239 Open 240-247 Random Strobe 248-255 Open 000-255 0%  100% GREEN 000-255 0%  100% BLUE 000-255 0%  100% WHITE 000-255 0%  100% RGBW EFFECT MODE 000-014 Blackout 015-047 Full On 048-095 Effect (see channel 17-1) 096-135 Number 1 to 9 (see channel 17-2) 136-175 Letter A to Z...
  • Page 32 088-095 Effect 11 096-103 Effect 12 104-111 Effect 13 112-119 Effect 14 120-127 Effect 15 128-135 Effect 16 136-143 Effect 17 144-151 Effect 18 152-159 Effect 19 160-167 Effect 20 168-175 Effect 21 176-183 Effect 22 184-191 Effect 23 192-199 Effect 24 200-207 Effect 25...
  • Page 33 210-232 Number – 8 233-255 Number – 9 RGBW BIG LETTER 000-021 No function 022-030 Letter – A 031-039 Letter – B 040-048 Letter – C 049-057 Letter – D 058-066 Letter – E 067-075 Letter – F 076-084 Letter – G 085-093 Letter –...
  • Page 34 RGBW LITTLE LETTER 000-021 No function 022-030 Letter – a 031-039 Letter – b 040-048 Letter – c 049-057 Letter – d 058-066 Letter – e 067-075 Letter – f 076-084 Letter – g 085-093 Letter – h 094-102 Letter – i 103-111 Letter –...
  • Page 35 074-127 Fast Open Fast Close 128-137 138-191 Slow Open Fast Close 192-201 202-255 Fast Open Slow Close STAR PATENT 000-011 Patent 1 012-023 Patent 2 024-035 Patent 3 036-047 Patent 4 048-059 Patent 5 060-071 Patent 6 072-083 Patent 7 084-095 Patent 8 096-107...
  • Page 36: Troubleshooting

    077-127 Slow  Fast 128-178 Slow Open Fast Close 179-242 Fast Open Slow Close 243-255 Random Open 6. Troubleshooting Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting: A. The unit does not work, no light and the fan does not work 1.
  • Page 37: Cleaning

    7. Cleaning The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics.
  • Page 39 Declaration of Conformity We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 89/336/EEC. EN55103-1: 2009+A1:2012; EN55103-2: 2009; EN61000-3-2: 2014; EN61000-3-3: 2013. & Harmonized Standard EN 60598-1:2015;...
  • Page 40 Innovation, Quality, Performance...