XP-1200F
Lamp ON/OFF
Press the MENU button until the
is blinking on the display. Pressing ENTER button
and the display will blink. Use DOWN and UP button to select the
(Lamp off) mode. Once the mode has been selected, press the ENTER button to
setup or automatically return to the main functions without any change after 8 seconds. To
go back to the functions without any change press the MENU button again.
Reset
Press the MENU button until the
is blinking on the display. Pressing ENTER button
and all channels of the unit will return to their standard position. To go back to the functions
press the MENU button again.
6.2 Home Position Adjust
Press MENU button for at least 5 seconds into offset mode to adjust the home position,
when you want to adjust gobo and color home position, you should be run
first , the functions are shown below:
MENU
Color offset
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
up to when the
is shown on the display. Pressing ENTER button and the display
will blink. Use DOWN and UP button to adjust the color home position. Once the color has
been selected, press the ENTER button to setup or automatically return to the offset
functions without any change press the MENU button again, To go back to the main
functions without any change after 8 seconds.
Effect offset
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
up to when the
is shown on the display. Pressing ENTER button and the display will
11-
(Lamp on) or
mode
Color offset (-127~127)
Effect offset (-127~127)
Dimmer offset (-127~127)

5. Lamp

MSI 1200W/S / HMI 1200/S K SFc10-4
Because of its high internal pressure, there might be a risk that the Discharge
lamp would explode during operation. The lamp emits intense UV radiation which
is harmful to the eyes and skin. The high luminance of the arc can cause severe
damage to the retina if looks directly at the lamp.
To protect the lamp, always turn off the lamp first (via control panel or DMX
controller) and let the unit run at least five minutes before switching off the mains
supply, never handle the lamp or luminaire when it is hot.
Do not touch the bulb with bare hands. If this happens, clean the lamp with
denatured alcohol and wipe it with a lint free cloth before installation.
The lamp generates UV radiation. Never operate the lamp without appropriate
shielding.
When lighting up, the lamp operates at high pressure and there is a slight risk of arc
tube rupture. The risk increases with age, temperature and improper handling of the
lamp. Do not use the lamp longer than its lifespan.
Make sure the lamp is located in the center of the reflector for the best projection.
Change Lamp
In case of replacement of the lamp or maintenance, do not open the
fixture within 15 minutes until the unit cools down after switching off.
WARNING
1. Turn off the power.
2.
Turn the head in horizontal position. Hinge must be on the upper side of the head. Turn
screws left and remove plastic cover. Loosen head screw and open the lamp cover
XP-1200F
8-