1. Safety Instructions Please read the instruction carefully which includes important information about the installation, usage and maintenance. WARNING Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction manual. Important: Damages caused by the disregard of this user manual are not subject to warranty.
the mains power immediately. DO NOT operate in dirty or dusty environment, do clean fixtures regularly. DO NOT touch any wire during operation as there might be a hazard of electric shock. Avoid power wires together twist other cables. ...
Page 5
Color Temperature 7800K Beam Angle 2° Display LCD Color Display Protection Rating IP20 Movement Pan: 540° Tilt: 270° Pan/Tilt Resolution 16bit Automatic Pan/Tilt correction Dimmer/Shutter 0~100% smooth dimming, various strobe speeds Color wheel 14 fixed colors plus open with rainbow effect Gobo wheel 16 fixed gobos plus open Prism...
Features 6000 hours long life light source Motorized focus Outstanding color macro effect Independent frost effect Dimension/Weight 350 × 253 × 565mm, 18Kgs 13.8" x 10" x 22.2"in, 39.7lbs 3. Description 3.1 Control Panel Wire Version:...
Page 7
POWERCON Version: 1. Monitor: To show the various menus and the selected function 2. Button: MENU To enter into move backward or leave the menu To go backward to move up in the menu DOWN To go forward to move down in the menu ENTER To perform the desired functions 3.
4. Gobo/Color and Lamp 4.1 Gobo/Color DANGER! Install the gobos with the device switched off only. Unplug from mains before changing gobos! CAUTION: Never unscrew the screws of the rotating gobo as the ball bearing will otherwise be opened! 4.2 Light Source Philips MSD Platinum 12R LL Because of its high internal pressure, there might be a risk that the Discharge lamp would ...
4.3 Changing the Lamp Do not use this lamp more than 6000 hours, using the lamp any longer than its set life could seriously damage your unit. Periodically checking the lamp running time, when the lamp reaches the 6000 hour mark, or close to it, we strongly suggest you switch the lamp out.
Finally reinstall the head cover, fastening it securely before reapplying power. Warning: The installing direction of lamp: 5. How To Set The Unit 5.1 Main Function Turn on the unit, press the MENU button into menu mode, and press the UP/DOWN button until the required function is shown on the monitor.
Page 12
DMX Settings To select DMX Settings, press the ENTER button to confirm, use the UP/DOWN button to select DMX Address, DMX Channel Mode, No DMX Status or View DMX Value. DMX Address —DMX512 address setting To select DMX Address, press the ENTER button to confirm. Use the UP/DOWN button to adjust the address from 001 to 500/497, press the ENTER button to store.
Page 13
Pan Invert To select Pan Invert, press the ENTER button to confirm. Use the UP/DOWN button to select No(normal) or Yes(pan invert), press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode. Tilt Invert To select Tilt Invert, press the ENTER button to confirm.
Page 14
Display Settings To select Display Settings, press the ENTER button to confirm, use the UP/DOWN button to select Display Invert, Backlight Intensity or Temperature Unit. Display Invert To select Display Invert, press the ENTER button to confirm, present mode will blink on the display, use the UP/DOWN button to select No(normal display) or Yes(invert display), press the ENTER button to store.
Page 15
Manual Test To select Manual Test, press the ENTER button to confirm, the present channel will show on the display, use the UP/DOWN button to select channel, press the ENTER button to confirm, then use the UP/DOWN button to adjust the value, press the ENTER button to store, the fixture will run as the channel value indicates.
Page 16
USB Upgrade File To select USB Upgrade File, press the ENTER button to confirm, USB upgrade file will show on the display, press the MENU button to exit. Fan State To select Fan State, press the ENTER button to confirm, fan state will show on the display, press the MENU button to exit.
Special Function Factory Settings To select Factory Settings, press the ENTER button to confirm, use the UP/DOWN button to select No(normal) or Yes(the fixture will reset to factory settings), press ENTER button to store. Press the MENU button to exit. RDM FUNCTIONS Select the MANUFACTURER menu to display the manufacturer of the fixture.
Page 18
Pan—Pan home position adjustment Enter offset mode, select Pan, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store.
Prism—Prism home position adjustment Enter offset mode, select Prism, press the ENTER button to confirm, the present position will blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the ENTER button to store.
ATTENTION Termination reduces signal errors and to avoid signal transmission problems and interference. It is always advisable to connect a DMX terminal (Resistance 120 ohm 1/4W between pin2 (DMX-) and pin3 (DMX+) of the last fixture). 1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit.
Unit 1 Unit 2 Unit 3 Unit 4 Channel mode Address Address Address Address 13 channels 16 channels 6.3 DMX 512 Configuration Please refer to below configurations to control the fixtures Attentions: 1. The unit will maintain the last condition until reset if you cut-off the DMX signal. 2.
Page 23
000-007 Close 008-255 Open SPECIAL FUNCTION 000-129 No Function 130-139 Lamp On 140-149 Reset XY 150-159 Reset Effect 160-199 No Function 200-209 Reset All 210-229 No Function 230-239 Lamp Off 240-255 No Function 16 Channels (Mode 2): CHANNEL VALUE FUNCTION 000-255 0 °...
FOCUS 000-255 0% ~ 100% FOCUS FINE 000-255 0% ~ 100% FROST 000-007 Close 008-255 Open SPECIAL FUNCTION 000-129 No Function 130-139 Lamp On 140-149 Reset XY 150-159 Reset Effect 160-199 No Function 200-209 Reset All 210-229 No Function 230-239 Lamp Off 240-255 No Function...
Page 26
4. Tilt Encoder Error Check if the tilt encoder is damaged. Check if the tilt encoder is in poor contact with the lead of the PCB board or disconnected. 5. CPU-B/C/D Error Check whether the 485 (DATA) leads on the PCB board are install in place or disconnected. Check whether the 485 (DATA) lead is disconnected.
9. Focus Reset Fail Check if the position of the focus mounting magnetic steel falls off or is damaged. Check if there are other interference items in the focus operating range. Check if the focus Hall elements is damaged. Check if the focus Hall elements is in poor contact with the lead of the PCB board or disconnected. Check if the focus motor is damaged.
or the previous one. 4. Try to use another DMX controller. 5. Check to see if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit. C. One of the channels is not working well 1.
Page 31
Declaration of Conformity We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 2014/30/EU. EN 55032: 2015; EN 61000-3-2: 2019; EN 61000-3-3: 2013; EN 55035: 2017 &...