Appendix D - ADM Error Codes
Error
Code
Error Name Error Description
Blue Inline
WMC1
Con. Fault
Red Hose
WMC2
Con. Fault
Red Inline
WMC3
Con. Fault
Blue Hose
WMC4
Con. Fault
Blue Tank
WMC5
Con. Fault
Red Tank
WMC6
Unexpected current to relay 1 Alarm
Con. Fault
Red Chiller
WMC7
Con. Fault
Blue Chiller
WMC8
Con. Fault
Motor
A general fault has occurred
WMH1
Controller
within the MCM
Fault
USB Update
The ADM tried to upload a
W0U0
Failed
system settings file but failed
The requested controlling
Invalid
value (pressure or flow) is
Setpoint
outside the limits of the
Request
system
WSC0
The shot that was entered for
Invalid Gel
the gel timer is not a valid
Timer
shot. This must be fixed before
Definition
the gel timer will function
properly
88
Error
Type
Cause
Shorted module
Deviation Internal hardware failure
System Settings file is
Alarm
corrupt
System incorrectly setup
Deviation
Shot incorrectly defined
Gel timer shot is below
the minimum dispense
amount or set for a
invalid pressure/flow
The MCM has
Deviation
determined that the gel
timer shot will not be
able to be executed
based parameters
entered in the ADM
Solution
If temperature is being affected by a zone that has
been disabled, replace heat module
Cycle power, if the error persists the MCM will need
to be replaced
Replace the system settings file with a backup or new
file
On the ADM go into the setup screens -> System->
and ensure that all pages have properly defined
values
Redefine shot with control parameters within the
limits of the system
Select a different shot or modify existing shot data
If you are certain that the shot is within parameters,
try running the Learn Mode routine found in the setup
screen Calibration. If the error persists, a gel shot
with reduced control parameters is required.
3A2797ZAA