Appendix D - ADM Error Codes
Error
Code
Error Name Error Description
Comm. Error
CAA2
Red Hose
Comm. Error
CAA3
Red Inline
Comm. Error
CAA6
Red Blanket
Comm. Error
CAA7
Red Chiller
Comm. Error
CAB1
Blue Inline
Comm. Error
CAB4
Blue Hose
Comm. Error
CAB5
Blue Blanket
Comm. Error
CAB8
Blue Chiller
Comm. Error
CAC1
Motor
Comm. Error
CAC2
MCM
Communication error
Comm. Error
CAC3
Red Tank
Comm. Error
CAC4
Blue Tank
Comm. Error
CAC5
Mix Head
Comm. Error
CAC6
Mix Head 2
Comm. Error
CAC7
Ratio Monitor
Comm. Error
CAC9
Small
Dispense Kit
Comm. Error
CACN
Gateway
Comm. Error
CACP
DGM
Comm. Error
CACR
Remote
Pendant
Voltex Mixer Module is Off line
Comm. Error
CAD1
(HFR Only)
Mixer
Gateway
CUCN
Heartbeat
Heartbeat Error
Error
Setpoint Not
The set point was not reached
D1A1
Reached
and the pump was shutdown
Setpoint Not
D2A1
The set point was not reached Deviation
Reached
78
Error
Type
Cause
Module missing power
Module not programmed Program the module
Alarm
Module bad
CAN cable to Voltex
Alarm
FCM3 is disconnected.
FCM3 failure.
PLC is not maintaining
heartbeat
Module missing power
Alarm
Module not programmed Program the module
Module Bad
Material restriction too
Deviation
high for requested flow
Pump cannot reach the
requested pressure
Pump cannot reach the
requested flow
Solution
Check power supply connection
Replace module
Reconnect, ensure cable. Verify proper LED
indications on Voltex FCM3.
Ensure PLC is triggering the heartbeat
Check power supply connection
Replace module
Reduce flow request
Increase restriction in the system
Decrease restriction in the system
3A2797ZAA