To set the on/off machine times:
1. Press
to enter the screen.
2. Press left or right arrow keys to highlight the day
selection column. Continue to press the left or right
arrow keys to select the desired day, work week
(Monday thru Friday), or full week (Sunday thru Sat-
urday) duration.
3. Press the up or down arrow keys to select the
desired hour to schedule the on or off machine
times.
4. Press
to enter the selected hour and select the
desired time (15 minute increments) for either
machine on or off to occur.
5. Press
and select either on or off for the time
duration selected.
Bar Color
Description
Green
Machine is ON
Red
Machine is OFF
Blue
Machine PrePoly Refresh Start
3A2797ZAA
Appendix B - ADM Setup Screens Overview
6. To erase times, repeat steps 1 thru 3 and press
once the desired time duration has been
selected.
NOTE: If times are entered in the weekly schedule, indi-
vidual days can not be erased.
NOTE: Set the Prepoly Timeout one minute beyond the
time it takes for the material to reach the middle sensor.
Cold Start Up Mode
Allows the user to select what mode the machine will
enter once the cold start-up is complete. Selecting no
change will leave the machine in either standby or night
modes circulating at the set low pressure percentage.
Auto High Pressure
Changes the machine to high pressure circulation when
the mode is changed from either standby or night
modes.
Calender Time Based Night Mode Conditioning
Screen
This screen shows a summary of Time Based Night
Mode on or off times that were set by the Time Based
Night Mode Conditioning Screen.