Data Exchange
Pointer
Description
Designation
231
Dynamic Mixer
Speed
232
Set Point.
Dynamic Mixer
234
Actual Speed
235
Dynamic Mixer Air
Nucleation On Time
236
237
Dynamic Mixer Air
Nucleation Off Time
238
239
Dynamic Mixer,
Motor Ramp Up
240
Time
241
Dynamic Mixer, On/
Off State/ Request
242
243
Dynamic Mixer, Air
Nucleation On/ Off
244
State/ Request
251
Recirculation Flow
Rate Set Point
252
253
Low pressure
Circulation
254
Percentage
Read System
260
Version
262
Read System Date
271
Cavitation Errors
Disabled
272
Reserved for Future
273-65, xxx
Use
3A2797ZAA
Appendix G - Communications Gateway Module Installation Kit
Comments, Data Element Descriptions
In RPM. Only valid if using Dynamic Mixer (Voltex) option.
In RPM. Only valid if using Dynamic Mixer (Voltex) option.
In milli-second increments. Only valid if using Dynamic Mixer
(Voltex) option, and "Air Nucleation" turned ON (System #4 setup
screen).
In milli-second increments. Only valid if using Dynamic Mixer
(Voltex) option, and "Air Nucleation" turned ON (System #4 setup
screen).
In milli-second increments. Only valid if using Dynamic Mixer
(Voltex) option.
1 = Motor On (read), or Turn ON Request (write). If sending a
Turn On Request, the system should be idle and Not dispensing.
1 = Air On (read), or Air ON Request (write). If sending a Turn On
Request, the system should be idle and Not dispensing.
Set (Write) or get (read) the recirculation flow rate set point in in
0.01 cc/sec, 0.01 g/sec units (HFR Systems with Circulation
Valves Installed).
Set (Write) or get (read) the Low pressure Circulation flow rate
percentage (System #2 Setup screen). Values of 10 – 90 %
allowed (NVH Systems only).
A 32-bit string in the format of 0xXXCCBBAA.
0xCC...Build Version
0xBB...Minor Version
0xAA...Major Version
A 32-bit string in the format of 0xDDCCBBAA.
0xDD...Year (0x0D corresponds to 2013)
0xCC...Month (0x0A corresponds to October)
0xBB...Day
0xAA...Day of Week (0x01 Corresponds to Monday)
Set (Write) or get (Read) if the Cavitation Error generation
logic is Disabled (= 1, not recommended for production use)
or Enabled (= 0, if logic is Active). Refer to "Cavitation Errors
Disabled" option on ADM Advanced #3 setup screen for
current state.
-----
Read/
Write
Write
Read
Read
Write
Read
Write
Read
Write
Read
Write
Read
Write
Read
Write
Read
Write
Read
Read
Read
Write
Read
-----
111