Graco HFR Setup page 16

Nvh foam - cart
Hide thumbs Also See for HFR:
Table of Contents

Advertisement

Component Identification
Main Power Switch
Located on top of the power distribution box, see
page
. The main power switch turns power
14
ON
and OFF
does not turn pumps or heat zones on.
16
. The main power switch
Circuit Breakers
Most circuit breakers are located inside the power dis-
tribution box. The main block of circuit breakers in the
power distribution box is shown below, with detailed
information in the following table. For more information
about items in the power distribution box, see power
distribution box manual.
CB1
CB2
CB5
ti19513a
Size
400V/
230V/
Ref.
3 phase
3 phase
CB1
63A
CB2
40A
CB5
5A
CB6
5A
CB9
40A
CB11
30A
400V/ 3 phase
ti19512a
CB11
CB6
230V/ 3 phase
CB9
Component
30A
Motor Control Module
40A
Primary Heater A
5A
Miscellaneous
5A
Miscellaneous
40A
Primary Heater B
30A
AC Power Pack
3A2797ZAA