Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and
mix chamber sizes may be less.
◆ Flow rate is independent of frequency 50/60 Hz.
approved.
‡ The maximum fluid working pressure for the base machine without hoses is 3000 psi (20.7 MPa, 207 bar). If
hoses rated at less than 3000 psi are installed, the system maximum fluid working pressure becomes the rating of
the hoses. If 2000 psi hoses were purchased and installed by Graco, the working pressure for the machine is
already setup for the lower 2000 psi (13.8 MPa, 138 bar) working pressure by Graco. If the machine was pur-
chased without hoses and aftermarket hoses rated at or above 3000 psi are to be installed, see instruction man-
ual 313998 for the procedure to setup the machine for higher rated hoses. The change in working pressure is
made by changing a rotary switch setting in the Motor Control Module. The minimum pressure rating for hoses is
2000 psi. Do not install hoses with a pressure rating lower than 2000 psi.
✖ See 400 V Power Requirements.
400 V Power Requirements
400 V systems are intended for International volt-
age requirements. Not for voltage requirements in
North America.
If a 400 volt configuration is operated in North
America, a special transformer rated for 400 V ("Y"
configuration (4 wire)) may be required.
North America mostly employs a 3 wire or Delta
configuration. The two configurations are not inter-
changeable.