Appendix D - ADM Error Codes
Error
Code
Error Name Error Description
When the pump tried to stall to
pressure the pump traveled
Pump Failed
F7D1
more than it should in normal
to Stall
operation (only applies to
dead-headed system)
Red Low
L111
Material Level
Low material level in tanks
Blue Low
L122
Material Level
Red High
L311
Material Level
High material level in tanks
Blue High
L322
Material Level
Red Auto
L6A1
Refill Timeout The tank stand has been filing
for a time greater than
Blue Auto
L6B2
expected
Refill Timeout
Red Tank
Possible Leak in Red Tank
L9AX
Leak
detected
Detected
L9BX
Blue Tank
Possible Leak in Blue Tank
Leak
detected
Detected
Red Tank
A level sensor had ceased
L8A1
Sensor
working
Failure
The volume of oil in the tank is
below the minimum level
MBH1 Low Oil Level
needed for the system to
properly operate
Low Mix
Oil level in AC Power Pack too
MBH3
Head Oil
low.
Level
The motor magnetism has
Low Motor
decreased to the point where
MBN1
Performance
performance is greatly
reduced
USB Logs
USB log has reached the
MMUX
Full
maximum entries
Material
N1D0
Dispense
Below Alarm
Material dispense is below the
Material
defined limit
Dispense
N2D0
Below
Deviation
Material
Dispense
Material dispense is above the
N3D0
Above
defined limit
Deviation
80
Error
Type
Cause
Failure of the dispense
valve
Deviation
Material leak
Out of material
Tanks low on material
Deviation
Loose/broken
connection
Bad level sensor
Deviation Defective fill valve
No material is actually
being fed
Deviation
Loose level sensor
connection
Bad level sensor
System did two or more
automatic tank fill
Deviation
operations without a
dispense during the
same time
Deviation Bad level sensor
Low oil level
Loose/bad connection
Bad level sensor
Alarm
Leak in hydraulic driver
Leak in the hydraulic
reservoir, heat
exchanger
Alarm
Level Sensor bad.
Function turned ON
without sensor installed.
Prolonged exposure to
Advisory
heat or high voltage
USB logs have not been
Advisory
downloaded
Alarm
Cogs in flow meter are
not turning
Deviation
Cable unplugged/loose
Deviation
power
Solution
Ensure the valve has a proper air supply and seals
properly. If not, service the valve as necessary.
Visually inspect the machine and hoses for sign of
leakage. NOTE: This error will display after 2 full
piston strokes so the leak will be substantial.
Fill tanks
Fill tanks with material
If the tanks appear to have plenty of material check to
make sure the level sensor is connected to the proper
port and that the cord is not damaged
Replace level sensor
If the tanks appear to have plenty of material check to
make sure the level sensor is connected to the proper
port and that the cord is not damaged
Make sure the feed pumps are operating properly
Check for loose or disconnected wires or plugs
Replace level sensor
Check hose connecions between tank output, and
pump inlet. Check tank fittings.
Replace level sensor
Check oil level and if low add more hydraulic fluid
Check to ensure the hydraulic oil level sensor is
properly connected to the MCM and that the wire has
not been damaged
Replace sensor
Inspect hydraulic driver end seals and early leak
detection tubing. Replace seals as necessary and
replace lost oil.
Inspect the hydraulic reservoir fittings and filter for
leaks. Repair or replace as necessary and replace
lost oil.
Add oil.
If error persists and performance can no longer
satisfy the user requirements the motor will need to
be replaced
Download USB logs to a memory stick
Uncheck the Enable USB errors on Advanced screen
4
Check that flow meter is matched to nominal pump
output
Check for loose or disconnected wires or plugs
3A2797ZAA