Appendix G - Communications Gateway Module Installation Kit
Data Exchange
Pointer
Description
Designation
Set or Read
183
Register
"Configurable Data
Command 2"
Assignment (Output
184
instance 9, O104 –
O119)
Set or Read
185
Register
"Configurable Data
Command 3"
Assignment (Output
186
instance 10, O120 –
O135)
Set or Read
187
Register
"Configurable Data
Command 4"
Assignment (Output
188
instance 11, O136 –
O151)
Mixed Material in
200
Current or Last
Dispense
Blue Material in
202
Current or Last
Dispense
Red Material in
204
Current or Last
Dispense
Mixed Material
206
Resettable Counter
Blue Material
208
Resettable Counter
Red Material
210
Resettable Counter
Pump Resettable
212
Counter
Reset All Resettable
213
Material Counters
Mixed Material Total
220
Counter
Blue Material Total
222
Counter
Red Material Total
224
Counter
Total Pump Cycle
226
Counter
110
Comments, Data Element Descriptions
Register assignments must be an Odd number, and correspond
to any Write Assignment in this Table. Once set (Write), the HFR/
NVH will remember the assignment, even after a power cycle.
Register assignments should be 16 bits wide, or smaller.
Register assignments must be an Odd number, and correspond
to any Write Assignment in this Table. Once set (Write), the HFR/
NVH will remember the assignment, even after a power cycle.
Register assignments should be 16 bits wide, or smaller.
Register assignments must be an Odd number, and correspond
to any Write Assignment in this Table. Once set (Write), the HFR/
NVH will remember the assignment, even after a power cycle.
Register assignments should be 16 bits wide, or smaller.
Sum of Blue and Red Materials Dispensed (In 0.01 CC or 0.01
Gram units)
(In 0.01 CC or 0.01 Gram units)
(In 0.01 CC or 0.01 Gram units)
Sum of Blue and Red Resettable Counters (In 0.01 CC or 0.01
Gram units)
(In 0.01 CC or 0.01 Gram units)
(In 0.01 CC or 0.01 Gram units)
(in pump cycles)
Will set all the resettable counters to 0. System must be idle
(Pumps NOT moving) for this command to execute.
Sum of Blue and Red material dispensed from HFR or NVH (In 1
CC or 1 Gram units)
Sum of Blue material dispensed from HFR or NVH (In 1 CC or 1
Gram units)
Sum of Red material dispensed from HFR or NVH (In 1 CC or 1
Gram units)
Total number of pump cycles for the NVH/ HFR system.
Read/
Write
Write
Read
Write
Read
Write
Read
Read
Read
Read
Read
Read
Read
Read
Read
Write
Read
Read
Read
3A2797ZAA