Appendix G - Communications Gateway Module Installation Kit
Data Exchange
Pointer
Description
Designation
Blue Material Chiller
98
Zone, temperature
Heater Zones
102
Enabled Bit Masks
103
Heater Zones On/
Off Bit Masks
104
Current Tank Level
120
Status
121
Tank Filling Control/
Status, Red Tank
122
123
Tank Filling Control/
Status, Blue Tank
124
130
Ratio, Setpoint
132
Ratio, Actual
108
Comments, Data Element Descriptions
Current Zone Actual Temperature, in 0.1 C
Bit 0 = Red Tank Zone Enabled (1) or Disabled (0).
Bit 1 = Blue Tank Zone Enabled or Disabled.
Bit 2 = Red Inline Heater Enabled or Disabled.
Bit 3 = Blue Inline Heater Enabled or Disabled.
Bit 4 = Red Hose Heater Enabled or Disabled.
Bit 5 – Blue Hose Heater Enabled or Disabled.
Bit 6 = Red Chiller Enabled or Disabled.
Bit 7 = Blue Chiller Enabled or Disabled.
Bit 0 = Red Tank Zone Turned ON (1)/ Off (0).
Bit 1 = Blue Tank Zone Turned ON/ Off.
Bit 2 = Red Inline Heater Turned ON/ Off.
Bit 3 = Blue Inline Heater Turned ON/ Off.
Bit 4 = Red Hose Heater Turned ON/ Off.
Bit 5 – Blue Hose Heater Turned ON/ Off.
Bit 6 = Red Chiller Turned ON/ Off.
Bit 7 = Blue Chiller Turned ON/ Off.
Least Significant Byte – Red Tank Level
nd
2
Significant Byte – Blue Tank Level
Level indications/ Byte:
1 = Material is below Low Level sensor.
2 = Material between Low and High Level (2
nd
3 = Tank Full (at 2
sensor, or above).
7 = Material at or above top sensor ("Report xxx High Level in bit
2" feature ON).
1 = Active Filling (Read) or Manual Fill Request (Write).
0 = Filling NOT Active (Read), or Abort Manual Fill (Write).
1 = Active Filling (Read) or Manual Fill Request (Write).
0 = Filling NOT Active (Read), or Abort Manual Fill (Write).
In 0.001:1 units of measure. So for instance, a value of 23680 =
23.680:1. Ratio may be inverted based on the setting of the
"Ratio:" control selection on the System #3 setup screen.
Ratios are either volumetric or weight depending upon the "Flow
Units" Selection on the ADM Advanced #2 setup screen.
In 0.001:1 units of measure. So for instance, a value of 23721 =
23.721:1. Ratio may be inverted based on the setting of the
"Ratio:" control selection on the System #3 setup screen. This
data is only valid if HFR or NVH has a Ratio Monitoring option
installed.
o
units
nd
) sensors.
3A2797ZAA
Read/
Write
Read
Read
Write
Read
Read
Write
Read
Write
Read
Read
Read