Graco HFR Setup page 33

Nvh foam - cart
Hide thumbs Also See for HFR:
Table of Contents

Advertisement

12.
Connect Material Hoses
NOTICE
Avoid routing hoses in walkway areas to prevent
operators from tripping on hoses running between
system components. This also prevents fittings
from leaking.
NOTE: Refer to F
. 15 on page 32 for visual clarity of
IG
the following steps.
a. Ensure main power is OFF
b. Ensure A (Red) and B (Blue) inlet valves on the
HFR and the material supply ball valves on the
tanks are closed.
c. Remove reducer fitting from the A (Red) con-
nection of the HFR fluid manifold. Install FTS in
the A (Red) material supply line between main
hose and whip hose. Ensure the FTS is facing
toward the fluid flow of material after installa-
tion. See Heated Hose manual for instructions.
Refer to F
. 15 and F
IG
3A2797ZAA
.
. 16.
IG
d. Remove reducer fitting from B (Blue) connec-
tion of the HFR fluid manifold (Models 24N573,
24N574 only). Install the provided additional
spacers near the location of the FTS for the
remaining material lines. Refer to F
F
. 16.
IG
HFR material
manifold
Remove
reducer
F
. 16: Material Manifold
IG
e. Install ball valves (optional) between main hose
and whip hose. Connect the main hose bundle
to the whip hose bundle.
NOTE: The ball valve kit is designed to fit in one orien-
tation only.
NOTICE
If using the ball valve kit, ensure the FTS does not
go through the ball valve. Failure to do so will result
in damage to the FTS and the inability to close the
ball valve.
f.
Assemble the hydraulic hose sections together
and place the assembled hose connection near
the FTS area. Refer to F
g. Connect A (Red) and B (Blue) hoses to A (Red)
and B (Blue) outlets on HFR fluid manifold (FM).
Hoses are color coded: solid red for compo-
nent A, solid blue for component B.
. 15 and
IG
A
B
. 15.
IG
Setup
33